Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to Resistance Set meter to measure resistance
Remove pump cover / plug

Measurement:

Test 1:
Measure the resistance between pump live and neutral connections.
Resistance vary by pump but should be greater than 120Ω.
Resistance on ErP pumps will be significantly higher.
(Greater than 1MΩ or O.L.)

Test 2:
Measure the resistance between pump live and earth connections.
Resistance should be greater than 1MΩ (or O.L).
Note:
For other designs of pump please refer to instruction
manual for which connection is live / neutral / earth.