WORCESTER GREENSTAR LIFE
GLOBALLY REPLACED
FAULT 224, 2963, 2964, 2965, 2966, 2967 - OVERHEAT
HEADER FOR FAULT CODE - OUTSIDE MODEL
FAULT 228 - FALSE FLAME
HEADER FOR FAULT CODE - OUTSIDE MODEL
FAULT 1065 - PRESSURE SENSOR FAULT
HEADER FOR FAULT CODE - OUTSIDE MODEL
FAULT 815 - LLH SENSOR FAULT
HEADER FOR FAULT CODE - OUTSIDE MODEL
FAULT 306 - FLAME AFTER DEMAND
HEADER FOR FAULT CODE - OUTSIDE MODEL
FAULT 1075 AND 1076 - HEATING BLOCK THERMISTOR FAULT
HEADER FOR FAULT CODE - OUTSIDE MODEL
FAULT 1073 AND 1074 - FLOW THERMISTOR FAULT
HEADER FOR FAULT CODE - OUTSIDE MODEL
FAULT 207, 1017, 2971 - SYSTEM PRESSURE TOO LOW
HEADER FOR FAULT CODE - OUTSIDE MODEL
FAULT 2970 - PRESSURE DROP IN SYSTEM TOO RAPID
HEADER FOR FAULT CODE - OUTSIDE MODEL
OBSERVATION BOILER SELF CHECK
ENSURE NO DEMANDS
FURTHER INVESTIGATION MAINS FUSE DUMMY
HEADER FOR MAINS FUSE INVESTIGATION - OUTSIDE MODEL
FAULT 214, 2961, 2962 - FAN FAULT
HEADER FOR FAULT CODE - OUTSIDE MODEL
OPERATION DHW
CH DEMAND OFF
OBSERVATION PUMP OVERRUN
ENSURE BOILER IS SET TO ECO MODE
ENSURE NO DEMAND
FAULT 234, 238, 2923, 2924, 2925, 2926, 2927, GAS VALVE ELECTRICAL FAULTS
HEADER FOR FAULT CODE - OUTSIDE MODEL
FAULT 232, 233, 235, 242, 244, 245, 249, 250, 251, 252, 253, 254, 257, 258, 259, 262, 263, 360, 362, 1025, 2908, 2914, 2915, 2916, 2931, 2940, 2946, 2957 CODE PLUG AND PCB FAULT CODES
HEADER FOR FAULT CODE - OUTSIDE MODEL
FAULT 1019 & 281 - PUMP PWM / HALL ISSUE
HEADER FOR FAULT CODE - OUTSIDE MODEL
QUICK ACCESS DATA AND INFORMATION
THE TABLE BELOW SHOW
LITE DIAGNOSTIC
DIAGNOSIS RELIES ON
INFORMATION DISPLAY OPERATION AND FAULT CODES
THE USER INTERFA
INFORMATION FAULT CODES (DETAILED)
THE APPLIANCE HAS 5
INFORMATION USER INTERFACE (DETAILED)
THE DISPLAY WILL SLE
HEADER FOR QUICK ACCESS DATA FLOW THERMISTOR
HEADER FOR QUICK ACCESS DATA
HEADER FOR QUICK ACCESS DATA HEAT BLOCK THERMISTOR
HEADER FOR QUICK ACCESS DATA
HEADER FOR QUICK ACCESS DATA GAS VALVE RESISTANCE
HEADER FOR QUICK ACCESS DATA
HEADER FOR QUICK ACCESS DATA PUMP AC RESISTANCE
HEADER FOR QUICK ACCESS DATA
HEADER FOR QUICK ACCESS DATA PUMP AC VOLTAGE
HEADER FOR QUICK ACCESS DATA
HEADER FOR QUICK ACCESS DATA PUMP DC VOLTAGE
HEADER FOR QUICK ACCESS DATA
HEADER FOR QUICK ACCESS DATA FAN RESISTANCES
HEADER FOR QUICK ACCESS DATA
HEADER FOR QUICK ACCESS DATA FAN VOLTAGE
HEADER FOR QUICK ACCESS DATA
HEADER FOR QUICK ACCESS DATA GAS VALVE VOLTAGE
HEADER FOR QUICK ACCESS DATA
HEADER FOR QUICK ACCESS DATA SPARK GENERATOR VOLTAGE
HEADER FOR QUICK ACCESS DATA
HEADER FOR QUICK ACCESS DATA SPARK GENERATOR RESISTANCE
HEADER FOR QUICK ACCESS DATA
FAULT 229, 2948, 2949, 2950, 2951 - FLAME LOSS AFTER IGNITION
HEADER FOR FAULT CODE - OUTSIDE MODEL
INFORMATION MAINTENANCE SETTINGS
THIS APPLIANCE HAS A
FAULT 2085, 2972 LOW MAINS VOLTAGE
HEADER FOR FAULT CODE - OUTSIDE MODEL
FAULT 2955, 2956 HYDRAULIC PARAMETERS
HEADER FOR FAULT CODE - OUTSIDE MODEL
FAULT 269, 363, 2920, 2952 FLAME MONITORING
HEADER FOR FAULT CODE - OUTSIDE MODEL
FAULT 2910 FLUE SYSTEM
HEADER FOR FAULT CODE - OUTSIDE MODEL
FAULT 309, 811, 1004, 1007, 1009, 1010, 1022, 1037, 1068, A11, A61, A91,
HEADER FOR FAULT CODE - OUTSIDE MODEL
INFORMATION CONNECTOR NAMES
WORCESTER BOSCH HAS
INFORMATION INSTALLER MODE AND MENUS
TO ENTER THE INSTALL
INFORMATION SERVICE MODE
SET THE BOILER INTO
BLANK FOR LITE DIAGNOSTIC
Z REDIRECT
BLANK FOR QADAI
Z REDIRECT
SHORTED TO EARTH CAUSING FALSE FLAME
ELECTRODE - C/W SPRING
RESTRICTED OR BLOCKED CAUSING FALSE FLAME
SIPHON - ASSEMBLY
FAULTY CAUSING FALSE FLAME
ELECTRODE - C/W SPRING
PASSING FALSE FLAME
GAS - VALVE
ERROR CODE
LOW LOSS HEADER SENSOR
LOW LOSS HEADER SETTINGS
CONTROL BOX SETTINGS
OPEN CIRCUIT STOPPING SPARK
HARNESS IGNITION CABLE
NO POWER TO SPARK GEN
CONTROL BOX - ACU
SPARK GENERATOR SECTION
HARNESS - 240V - COMBI/SYSTEM
RESTRICTED OR BLOCKED PREVENTING IGNITION
SIPHON - ASSEMBLY
STUCK PREVENTING IGNITION
NON - RETURN - VALVE - C5 (BEARING PLATE)
DAMAGED PREVENTING IGNITION
BURNER
GAS VALVE DAMAGED PCB
CONTROL BOX - ACU AND GAS VALVE
RESTRICTED PREVENTING IGNITION
VENTURI
SPARK ELECTRODES FAULTY
ELECTRODE - C/W SPRING
OPEN CIRCUIT
HARNESS GND CABLE
SHORTED
PUMP - UPM3
NO VOLTAGE TO PUMP
CONTROL BOX - ACU
PUMP SECTION SELF CHECK
HARNESS - 240V - COMBI/SYSTEM
PUMP DC SECTION FAULTY STOPPING PUMP AT SELF CHECK
HARNESS - 24V - CHG
PUMP DC HALL/PWN SECTION FAULTY STOPPING PUMP AT SELF CHECK
CONTROL BOX - ACU
PUMP DC SECTION FAULTY
HARNESS - 24V - CHG
PUMP DC HALL/PWN SECTION FAULTY
CONTROL BOX - ACU
NO AC VOLTAGE TO PUMP PUMP/PWM FAULT CODE
CONTROL BOX - ACU
PUMP SECTION ERROR CODE
HARNESS - 240V - COMBI/SYSTEM
PUMP DC SECTION FAULTY STOPPING PUMP AT SELF CHECK PUMP/PWM FAULT CODE
HARNESS - 24V - CHG
PUMP DC HALL/PWN SECTION FAULTY STOPPING PUMP FAULT CODE
CONTROL BOX - ACU
NO AC VOLTAGE TO PUMP PUMP/PWM FAULT CODE OVERHEAT
CONTROL BOX - ACU
PUMP SECTION OVERHEAT
HARNESS - 240V - COMBI/SYSTEM
PUMP DC SECTION FAULTY STOPPING PUMP AT SELF CHECK PUMP/PWM FAULT CODE OVERHEAT
HARNESS - 24V - CHG
PUMP DC HALL/PWN SECTION FAULTY STOPPING PUMP FAULT CODE OVERHEAT
CONTROL BOX - ACU
BLANK FOR DETAILED DISPLAY INFORMATION
Z REDIRECT
BLANK FOR DETAILED FAULT CODES INFORMATION
Z REDIRECT
NO VOLTAGE TO PRESSURE SENSOR
CONTROL BOX - ACU
PRESSURE SENSOR SECTION
HARNESS - 24V - CHG
FAULTY QADAI
SENSOR 18MM (FLOW)
FAULTY QADAI
SENSOR - TEMPERATURE (HEATING BLOCK)
SOLENOID FAILED QADAI
GAS - VALVE
NO VOLTAGE TO GAS VALVE QADAI
CONTROL BOX - ACU
FAULTY QADAI
PUMP - UPM3
NO POWER TO PUMP QADAI
CONTROL BOX - ACU
DC PUMP VOLTAGE
CONTROL BOX - ACU
FAN VOLTAGES WRONG QADAI
CONTROL BOX - ACU
NO POWER TO SPARK GENERATOR QADAI
CONTROL BOX - ACU
FAULTY QADAI
IGNITION - TRANSFORMER
INTERNAL FAULT
CONTROL BOX - ACU
MISALIGNED OR WATER INGRESS
PCB OR APPLIANCE CONNECTIONS
WRONG CODE PLUG TYPE
CODE PLUG
POOR FITMENT CAUSING ERROR CODES
THERMISTOR FITMENT
OUT OF CALIBRATION CAUSING OVERHEAT
SENSOR 18MM (FLOW)
FAULTY CAUSING OVERHEAT
SENSOR - TEMPERATURE (HEATING BLOCK)
BLANK FOR INFORMATION ON FLAME LOSS
Z REDIRECT
LOW CAUSING BAFFLING
GAS INLET PRESSURE
PARTIALLY STUCK CAUSING NO RECTIFICATION
NON - RETURN - VALVE - C5 (BEARING PLATE)
RECTIFICATION SECTION OPEN CIRCUIT
HARNESS - 24V - CHG
LOW CAUSING RECTIFICATION ISSUES
GAS INLET PRESSURE
RESTRICTED CAUSING FLAME LOSS
SIPHON - ASSEMBLY
LOW WHEN RUNNING ON MAX RATE
GAS INLET PRESSURE
LOW CAUSING FLAME LOSS
GAS INLET PRESSURE
RECTIFICATION ELECTRODE CAUSING FLAME LOSS AT MINIMUM
ELECTRODE - C/W SPRING
BLANK FOR FLAME LOSS FURTHER INVESTIGATION
Z REDIRECT
RECTIFICATION ELECTRODE CAUSING FLAME LOSS
ELECTRODE - C/W SPRING
CAUSING FLAME LOSS
BURNER
RESTRICTED CAUSING FLAME LOSS
FLUEWAYS
BLANK FOR INFORMATION CASE REMOVAL
Z REDIRECT
LOW CAUSING FLAME LOSS AT MAXIMUM
GAS INLET PRESSURE
BLANK FOR INFORMATION MAINTENANCE SETTINGS
Z REDIRECT
DISPLAYING LOW MAINS VOLTAGE FAULT
CONTROL BOX - ACU
HYDRAULIC SETTINGS
CONTROL BOX SETTINGS
DISPLAYING HYDRAULIC PARAMETERS FAULT
CONTROL BOX - ACU
SHORTED TO EARTH CAUSING FLAME MONITORING FAULT
ELECTRODE - C/W SPRING
FAULTY CAUSING FLAME MONITORING FAULT
ELECTRODE - C/W SPRING
RECTIFICATION SECTION SHORTED
HARNESS - 24V - CHG
RESTRICTED OR BLOCKED CAUSING FLUE FAULT ERROR
SIPHON - ASSEMBLY
FLUE FAULT WONT RESET
CONTROL BOX - ACU
GAS VALVE SECTION FAULTY
HARNESS - 24V - CHG
BLOWING FUSE
FAN
SHORTED
IGNITION - TRANSFORMER
RESTRICTED PREVENTING RECTIFICATION
SIPHON - ASSEMBLY
RESTRICTED CAUSING FLAME LOSS
VENTURI
BREACHED CAUSING FAILED FGA FLAME LOSS
FLUE / BURNER SEALS
BREACHED CAUSING FLAME LOSS
FLUE / BURNER SEALS
BREACHED CAUSING FLUE FAULT
FLUE / BURNER SEALS
RESTRICTED CAUSING FGA FAIL
FLUEWAYS
FAULTY CAUSINF ERROR CODE
SENSOR - TEMPERATURE (HEATING BLOCK)
OUT OF CALIBRATION ACTIVATING FROST (PUMP)
SENSOR 18MM (FLOW)
CAUSING POOR CH
AIR IN BOILER OR SYSTEM
FULLY CLOSED CAUSING POOR CH
VALVE - CH
CAUSING NO CH
AIR IN BOILER OR SYSTEM
FAN VOLTAGES INCORRECT 2
CONTROL BOX - ACU
CAUSING OVERHEAT
AIR IN BOILER OR SYSTEM
BLANK FOR INFORMATION CONNECTOR NAMES
Z REDIRECT
LOW CAUSING COMBUSTION ISSUES
GAS INLET PRESSURE
POOR FITMENT CAUSING POOR CH
THERMISTOR FITMENT
CLOSED CAUSING OVERHEAT
VALVE - CH
WEAK OR SLOW POOR CH RADS NO OR POOR HEAT
PUMP - UPM3
RECTIFICATION SECTION OPEN CIRCUIT DROPPING OUT AT MINIMUM
HARNESS - 24V - CHG
FAN SECTION
HARNESS - 240V - COMBI/SYSTEM
OUT OF CALIBRATION ACTIVATING FROST (PUMP)
SENSOR - TEMPERATURE (HEATING BLOCK)
OUT OF CALIBRATION CAUSING POOR CH
SENSOR - TEMPERATURE (HEATING BLOCK)
FAULTY CAUSING ERROR CODE
SENSOR 18MM (FLOW)
OUT OF CALIBRATION PREVENTING DEMAND
SENSOR 18MM (FLOW)
OUT OF CALIBRATION PREVENTING DEMAND
SENSOR - TEMPERATURE (HEATING BLOCK)
ACTIVATED CORRECTLY 2
APPLIANCE FROST PROTECTION (FIRING)
OUT OF CALIBRATION ACTIVATING FROST PROTECTION (FIRING) - NO FROST STAT
SENSOR 18MM (FLOW)
OUT OF CALIBRATION ACTIVATING FROST PROTECTION (FIRING) - NO FROST STAT
SENSOR - TEMPERATURE (HEATING BLOCK)
ACTIVATED CORRECTLY
EXTERNAL FROST PROTECTION (FROST AND OR PIPE STAT)
ACTIVATED CORRECTLY
APPLIANCE FROST PROTECTION (FIRING)
OUT OF CALIBRATION ACTIVATING FROST PROTECTION (FIRING)
SENSOR 18MM (FLOW)
OUT OF CALIBRATION ACTIVATING FROST PROTECTION (FIRING)
SENSOR - TEMPERATURE (HEATING BLOCK)
FROST PROTECTION OPERATING INCORRECTLY (PUMP)
CONTROL BOX - ACU
CORRECTLY ACTIVATED
EXTERNAL FROST PROTECTION (LOW LOSS HEADER)
OUT OF CALIBRATION ACTIVATING FROST PROTECTION
LOW LOSS HEADER SENSOR
NO CH RESPONSE - NO VOLTAGE TO CONTROLS NO OUTDOOR SENSOR
CONTROL BOX - ACU
PUMP OUTPUT SETTINGS
CONTROL BOX SETTINGS
LOW LIMITING OUTPUT
GAS INLET PRESSURE
RESTRICTED
FLUE
PARTIALLY RESTRICTED AFFECTING OUTPUT
NON - RETURN - VALVE - C5 (BEARING PLATE)
RESTRICTED LIMITING OUTPUT
BURNER
HEATING OUTPUT SETTINGS
CONTROL BOX SETTINGS
MAX CH FLOW TEMPERATURE SETTING
CONTROL BOX SETTINGS
LOW CH OUTPUT
CONTROL BOX - ACU
OUT OF CALIBRATION AFFECTING CH OPERATION
LOW LOSS HEADER SENSOR
BLANK FOR OPTIONAL DIVERTER VALVE ONLY
Z REDIRECT
BLOWN
FUSE (FUSED SPUR)
BLOWN
FUSE INTERNAL 5A
SHORTED BLANK DISPLAY
HARNESS - 24V - CHG
FAN VOLTAGES INCORRECT 2 FAULT 2910
CONTROL BOX - ACU
FAN SECTION DEMAND FAULT 2910
HARNESS - 240V - COMBI/SYSTEM
BLANK FOR INFORMATION SERVICE MODE
Z REDIRECT
RESTRICTED OR BLOCKED CAUSING BAFFLING
SIPHON - ASSEMBLY
PARTIALLY STUCK CAUSING BAFFLING
NON - RETURN - VALVE - C5 (BEARING PLATE)
BLANK FOR TYPE OF DIAGNOSTIC PROCEDURE
Z REDIRECT
RESTRICTED CAUSING BAFFLING
VENTURI
ACTIVATED CORRECTLY
APPLIANCE FROST PROTECTION (PUMP)
NO OR LOW CHARGE
EXPANSION - VESSEL - 10L
PATIALLY OR FULLY CLOSED CAUSING POOR CH
VALVE - CH
WEAK OR SLOW POOR CH BOILER RUNNING AT LOW ONLY
PUMP - UPM3
OUT OF CALIBRATION CAUSING POOR CH
SENSOR 18MM (FLOW)
RESTRICTED AFFECTING FGA
SIPHON - ASSEMBLY
RESTRICTED AFFECTING FGA
VENTURI
CAUSING POOR COMBUSTION FGA
BURNER
RESTRICTED OR BLOCKED CAUSING FLAME AFTER DEMAND ERROR
SIPHON - ASSEMBLY
PASSING
GAS - VALVE
FAN VOLTAGES INCORRECT
CONTROL BOX - ACU
OPEN CIRCUIT WHEN COOL
TEMPERATURE LIMITER
WEAK OR SLOW CAUSING OVERHEAT
PUMP - UPM3
BLANK FOR FAULT CODES
Z REDIRECT
BLOCKED ERROR CODE
PRESSURE - SENSOR (BLOCKAGE)
BLOCKED LOW PRESSURE WARNING
PRESSURE - SENSOR (BLOCKAGE)
FAN SECTION DEMAND
HARNESS - 240V - COMBI/SYSTEM
SOLENOID FAILED
GAS - VALVE
DISPLAYING GAS VALVE ELECTRICAL FAULT
CONTROL BOX - ACU
DISPLAYING PRESSURE DROP FAULT
CONTROL BOX - ACU
BREACHED CAUSING FAILED FGA 2
FLUE / BURNER SEALS
BREACHED CAUSING FAILED FGA
FLUE / BURNER SEALS
FAULTY CAUSING ERROR CODE
CODE PLUG
SHORTED
PRESSURE - SENSOR
SHORTED TO EARTH CAUSING FALSE FLAME
HARNESS - 24V - CHG
DISPLAYING FALSE FLAME FAULT
CONTROL BOX - ACU
LOW CAUSING ERROR CODE
SYSTEM PRESSURE
DISPLAYING LLH FAULT
CONTROL BOX - ACU
DISPLAYING LLH FAULT WITH LLH
CONTROL BOX - ACU
NOT GENERATING SPARK
IGNITION - TRANSFORMER
RESTRICTED PREVENTING IGNITON
FLUEWAYS
LOW PREVENTING IGNITION
GAS INLET PRESSURE
NO POWER TO GAS VALVE
CONTROL BOX - ACU
GAS VALVE HARNESS DAMAGED PCB
CONTROL BOX - ACU - 8700 AND HARNESS ASSEMBLY HV AND IGNITION
NOT OPENING
GAS - VALVE
OPENING BUT WRONG MIX FOR IGNITION
GAS - VALVE
ELECTRODE GND SECTION OPEN CIRCUIT
HARNESS - 24V - CHG
PUMP SECTION SHORTED
HARNESS - 240V - COMBI/SYSTEM
NOT RUNNING AT STARTUP
PUMP - UPM3
DC HALL/PWM SIDE FAULTY
PUMP - UPM3
NOT RUNNING CAUSING ERROR CODE
PUMP - UPM3
NOT RUNNING CAUSING OVERHEAT
PUMP - UPM3
PUMP OVERRUN SET INCORRECTLY
CONTROL BOX SETTINGS
ELECTRICALLY FAILED
PRESSURE - SENSOR
PUMP OVERRUN OPERATION INCORRECT
CONTROL BOX - ACU
DISPLAYING PRESSURE SENSOR FAULT
CONTROL BOX - ACU
FLOW THERMISTOR
RESULT AS EXPECTED
HEATING BLOCK THERMISTOR
RESULT AS EXPECTED
GAS VALVE
RESULT AS EXPECTED
VOLTAGE TO GAS VALVE
RESULT AS EXPECTED
HEATING BLOCK THERMISTOR SECTION
HARNESS - 24V - CHG
PUMP AC
RESULT AS EXPECTED
PCB PUMP VOLTAGE AC
RESULT AS EXPECTED
PCB PUMP VOLTAGE DC
RESULT AS EXPECTED
FAN
RESULT AS EXPECTED
PCB VOLTAGE TO FAN
RESULT AS EXPECTED
DISPLAYING HEATING BLOCK THERMISOT FAULT
CONTROL BOX - ACU
PCB VOLTAGE TO SPARK GENERATOR
RESULT AS EXPECTED
SPARK GENERATOR
RESULT AS EXPECTED
BLANK FOR CODE PLUG/PCB RELATED FAULTS
Z REDIRECT
BLOCKED OVERHEAT
PRESSURE GAUGE
LOW CAUSING OVERHEAT
SYSTEM PRESSURE
RESTRICTED AFFECTING RECTIFICATION
FLUEWAYS
NOT RECTIFYING
CONTROL BOX - ACU
RECTIFICATION ELECTRODE NOT ESTABLISHING
ELECTRODE - C/W SPRING
WRONG MIX ON MAXIMUM
GAS - VALVE
MIX WRONG CAUSING FLAME LOSS AT MAXIMUM
GAS - VALVE
FLAME LOSS ERRORS
CONTROL BOX - ACU
MIX WRONG CAUSING FLAME LOSS AT MINIMUM
GAS - VALVE
WRONG MIX CAUSING FLAME LOSS AT MAXIMUM 2
GAS - VALVE
WRONG MIX CAUSING FLAME LOSS AT MINIMUM 2
GAS - VALVE
BLANK FOR LOW VOLTAGE RESET
Z REDIRECT
BLANK FOR FAULT HYDRAULIC PARAMETERS
Z REDIRECT
FLAME MONITORING FAULTS
NO FAULT - RESET AFTER LOCKOUT
SHORTED TO EARTH CAUSING FLAME MONITORING FAULT
HARNESS - 24V - CHG
FLAME MONITORING FAULT
CONTROL BOX - ACU
FLUE FAULT
NO FAULT - RESET AFTER LOCKOUT
FAN SECTION SHORTED
HARNESS - 240V - COMBI/SYSTEM
NO FAULT FOUND FOR FUSE FAILURE
NO FAULT FOUND FUSE INVESTIGATION
SPARK GENERATOR SECTION SHORTED
HARNESS - 240V - COMBI/SYSTEM
BLOCKED POOR CH
PRESSURE GAUGE
LOW CAUSING POOR CH
SYSTEM PRESSURE
BLOCKED NO CH
PRESSURE GAUGE
LOW CAUSING NO CH
SYSTEM PRESSURE
DISPLAYING FALSE FLAME
CONTROL BOX - ACU
RECTIFICATION ELECTRODE NOT ESTABLISHING DROPPING OUT AT MINIMUM
ELECTRODE - C/W SPRING
WRONG MIX ON MINIMUM
GAS - VALVE
DISPLAYING FLOW THERMISOTR FAULT
CONTROL BOX - ACU
FLOW THERMISTOR SECTION
HARNESS - 24V - CHG
MK2 PCB AND CODE PLUG FITTED TO MK1 APPLIANCE
WRONG PARTS FITTED
BLOCKED LOW PRESSURE WARNING
PRESSURE GAUGE
LOW CAUSING ERROR ON STARTUP
SYSTEM PRESSURE
DISPLAYING LOW PRESSURE ERROR INCORRECTLY
CONTROL BOX - ACU
NOT REGISTERING DEMAND TO FAN
CONTROL BOX - ACU
CH DEMAND WHEN SHOULD NOT 240V CONTROLS
CONTROL BOX - ACU
CH DEMAND WHEN SHOULD NOT 240V CONTROLS NO EXTERNAL FROST STAT
CONTROL BOX - ACU
FROST PROTECTION (PUMP) ACTIVATING INCORRECTLY
CONTROL BOX - ACU
NOT RESPONDING TO CH DEMAND
CONTROL BOX - ACU
RESTRICTED LOWERING OUTPUT
FLUEWAYS
LOW CH OUTPUT WITH LLH
CONTROL BOX - ACU
NO REASON FOUND FOR OVERHEAT
NO FAULT FOUND - OVERHEAT INVESTIGATION
TRIPPING EARLY
TEMPERATURE LIMITER
TEMPERATURE CONTROL FAULTY RUNNING TOO HOT
CONTROL BOX - ACU
BLANK FOR OPTIONAL DIVERTER VALVE ONLY 2
Z REDIRECT
NO OUTPUT
CONTROL BOX - ACU
RESTRICTED CAUSING BAFFLING
FLUEWAYS
RESTRICTED OR BLOCKED
PIPE - EXPANSION - VESSEL - 10L
WRONG MIX ON MAX AND MIN
GAS - VALVE
STUCK IN OVERHEAT WILL NOT RESET
CONTROL BOX - ACU
OVERHEAT THERMOSTAT SECTION
HARNESS - 24V - CHG
NOT READING PRESSURE SENSOR VOLTAGE
CONTROL BOX - ACU
FALSE FLAME FAULTS
NO FAULT - RESET AFTER LOCKOUT
GAS VALVE SECTION
HARNESS - 24V - CHG
BLANK FOR GAS VALVE ELECTRICAL FAULTS
Z REDIRECT
BLANK FOR SYSTEM PRESSURE DROP
Z REDIRECT
BLOCKED ERROR CODE
PRESSURE GAUGE
WRONG MIX CAUSING BAFFLING
GAS - VALVE
NO PRESSURE DROP OBSERVED
CHARACTERISTIC TEST FROM PRESSURE GAS INLET AND DROP
PRESSURE DROPS BELOW A SATISFACTORY LEVEL
CHARACTERISTIC TEST FROM PRESSURE GAS INLET AND DROP
PUMP OVERRUN SETTING INCORRECT FOR THE SYSTEM
CHARACTERISTIC TEST FROM OBSERVATION PUMP OVERRUN
PUMP DOES NOT OVERRUN FOR THE TIME SET ON CH
CHARACTERISTIC TEST FROM OBSERVATION PUMP OVERRUN
SYSTEM PRESSURE IS CORRECT BUT DOES NOT INCREASE
CHARACTERISTIC TEST FROM INSPECTION PRESSURE SYSTEM
SYSTEM PRESSURE LOW
CHARACTERISTIC TEST FROM INSPECTION PRESSURE SYSTEM
SYSTEM PRESSURE IS CORRECT BUT DOES NOT INCREASE
CHARACTERISTIC TEST FROM INSPECTION PRESSURE SYSTEM
SYSTEM PRESSURE LOW
CHARACTERISTIC TEST FROM INSPECTION PRESSURE SYSTEM
BURNER DROPS OUT ON MAXIMUM RATE
CHARACTERISTIC TEST FROM COMBUSTION TEST MAX AND MINIMUM
FLAME DROPS OUT AT MAXIMUM
CHARACTERISTIC TEST FROM PRESSURE GAS INLET AND DROP
FLAME DROPS OUT AT MINIMUM
CHARACTERISTIC TEST FROM PRESSURE GAS INLET AND DROP
FGA READINGS INCORRECT AT MAXIMUM
CHARACTERISTIC TEST FROM PRESSURE GAS INLET AND DROP
FGA READING INCORRECT AT MINIMUM
CHARACTERISTIC TEST FROM PRESSURE GAS INLET AND DROP
SYSTEM PRESSURE IS CORRECT BUT DOES NOT INCREASE
CHARACTERISTIC TEST FROM INSPECTION PRESSURE SYSTEM
SYSTEM PRESSURE LOW
CHARACTERISTIC TEST FROM INSPECTION PRESSURE SYSTEM
FAN DOES NOT RUN, NO FAULT CODE DISPLAYED
CHARACTERISTIC TEST FROM OBSERVATION FAN RUNS CH DEMAND
SYSTEM PRESSURE IS CORRECT BUT DOES NOT INCREASE
CHARACTERISTIC TEST FROM INSPECTION PRESSURE SYSTEM
SYSTEM PRESSURE LOW
CHARACTERISTIC TEST FROM INSPECTION PRESSURE SYSTEM
FAN RELATED FAULT CODE SHOWN
CHARACTERISTIC TEST FROM OBSERVATION FAN RUNS CH DEMAND
LOW SYSTEM PRESSURE WARNING / FAULT
CHARACTERISTIC TEST FROM OBSERVATION BOILER SELF CHECK
RESISTANCE NOT AS EXPECTED
CHARACTERISTIC TEST FROM RESISTANCE FLOW THERMISTOR AND HARNESS
SYSTEM PRESSURE IS CORRECT BUT DOES NOT INCREASE
CHARACTERISTIC TEST FROM INSPECTION PRESSURE SYSTEM
FLOW THERMISTOR NOT FITTED
CHARACTERISTIC TEST FROM RESISTANCE FLOW THERMISTOR AND HARNESS
SYSTEM PRESSURE LOW
CHARACTERISTIC TEST FROM INSPECTION PRESSURE SYSTEM
APPLIANCE DOES NOT RECOGNISE DHW DEMAND
CHARACTERISTIC TEST FROM OPERATION DHW
APPLIANCE RECOGNISES DHW DEMAND BUT OPERATION UNSATISFACTORY
CHARACTERISTIC TEST FROM OPERATION DHW
BOILER GOES TO OVERHEAT BEFORE REACHING TEMPERATURE
CHARACTERISTIC TEST FROM OBSERVATION RUN TO MAX TEMP-OVERHEAT OCCUR
TEMPERATURE EXCEEDS 88°C AND BOILER STILL FIRING
CHARACTERISTIC TEST FROM OBSERVATION RUN TO MAX TEMP-OVERHEAT OCCUR
BURNER IGNITES BUT BAFFLES / NOISY - COMBUSTION ISSUE
CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION
BURNER IGNITES BUT DOES NOT ESTABLISH (FLAME SYMBOL DOES NOT ILLUMINATE) - RECTIFICATION ISSUE
CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION
BURNER DOES NOT IGNITE - IGNITION ISSUE
CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION
PUMP DOES NOT RUN
CHARACTERISTIC TEST FROM OBSERVATION BOILER SELF CHECK
BOILER ATTEMPTS TO FIRE AFTER SELF CHECK
CHARACTERISTIC TEST FROM OBSERVATION BOILER SELF CHECK
PUMP RUNS CONTINUOUSLY AFTER SELF CHECK
CHARACTERISTIC TEST FROM OBSERVATION BOILER SELF CHECK
BOILER REACHES TEMPERATURE BUT SYSTEM DOES NOT HEAT
CHARACTERISTIC TEST FROM OPERATION CH
BOILER TEMPERATURE AND SYSTEM TEMPERATURE LOW
CHARACTERISTIC TEST FROM OPERATION CH
EXCESSIVE SYSTEM PRESSURE RISE
CHARACTERISTIC TEST FROM OPERATION CH
COMBUSTION TEST FAILED
CHARACTERISTIC TEST FROM COMBUSTION TEST MAX AND MINIMUM
BURNER DROPS OUT ON MINIMUM RATE
CHARACTERISTIC TEST FROM COMBUSTION TEST MAX AND MINIMUM
10/11/2023 08:49:39 2311_1_46_1 22/02/2024 10:32:23
27/11/2023 10:12:06
RESISTANCE RECTIFICATION CIRCUIT TO EARTH
{GAINPCBACS}
DISCONNECT LV1 FROM THE PCB
RESISTANCE RECTIFICATION ELECTRODE TO EARTH
DISCONNECT RECTIFICATION LEAD FROM ELECTRODE (LEFT ELECTRODE)
RESISTANCE IGNITION LEAD
DISCONNECT IGNITION LEAD FROM SPARK GENERATOR AND ELECTRODE ASSEMBLY
RESISTANCE GAS VALVE AND HARNESS
{GAINPCBACS}
DISCONNECT LV1 FROM THE PCB
RESISTANCE GAS VALVE
DISCONNECT PLUG FROM GAS VALVE
RESISTANCE HARNESS GND CABLE
REMOVE CONNECTOR FROM THE MIDDLE ELECTRODE
RESISTANCE PUMP AND HARNESS
DISCONNECT CONNECTOR HV1 FROM THE PCB
RESISTANCE PUMP
REMOVE MAINS CONNECTION FROM PUMP
VOLTAGE PUMP AT PCB
{GAINPCBACS}
OBSERVATION DOES PUMP RUN
NO DEMAND
OBSERVATION DOES PUMP RUN WITH DC CONNECTOR REMOVED?
REMOVE THE DC PUMP CONNECTOR
NO DEMAND
VOLTAGE PUMP AT PCB
{GAINPCBACS}
OBSERVATION DOES PUMP RUN WITH DC CONNECTOR REMOVED?
REMOVE THE DC PUMP CONNECTOR
NO DEMAND
VOLTAGE PUMP AT PCB
{GAINPCBACS}
VOLTAGE PRESSURE SENSOR (PRESSURE)
{GAINPCBACS}
RESISTANCE FLOW THERMISTOR AND HARNESS
REMOVE CONNECTOR LV1 FROM THE PCB
RESISTANCE HEATING BLOCK THERMISTOR AND HARNESS
REMOVE CONNECTOR LV1 FROM THE PCB
RESISTANCE FLOW THERMISTOR
DISCONNECT LEADS TO FLOW THERMISTOR
RESISTANCE HEATING BLOCK THERMISTOR
REMOVE CONNECTOR FROM THE HEATING BLOCK THERMISTOR
RESISTANCE HEATING BLOCK THERMISTOR
REMOVE CONNECTOR FROM THE HEATING BLOCK THERMISTOR
RESISTANCE GAS VALVE
DISCONNECT PLUG FROM GAS VALVE
VOLTAGE GAS VALVE AT PCB
{GAINPCBACS}
RESISTANCE PUMP
REMOVE MAINS CONNECTION FROM PUMP
VOLTAGE PUMP AT PCB
{GAINPCBACS}
VOLTAGE DC PUMP
REMOVE THE DC CONNECTOR FROM THE PUMP
ENSURE NO DEMAND
RESISTANCE FAN
REMOVE CONNECTOR FROM FAN
VOLTAGE FAN AT PCB
{GAINPCBACS}
REMOVE THE CONNECTOR FROM THE FAN ASSEMBLY AND MAKE SAFE
VOLTAGE SPARK GENERATOR AT PCB
{GAINPCBACS}
RESISTANCE SPARK GENERATOR
UNPLUG MAINS CONNECTION FROM UNDERNEATH SPARK GENERATOR
RESISTANCE RECTIFICATION LEAD
{GAINPCBACS}
DISCONNECT RECTIFICATION LEAD FROM ELECTRODE ASSEMBLY
VOLTAGE MAINS POWER IN (LOW VOLTAGE)
{GAINPCBACS}
RESISTANCE RECTIFICATION CIRCUIT TO EARTH
{GAINPCBACS}
DISCONNECT LV1 FROM THE PCB
RESISTANCE RECTIFICATION ELECTRODE TO EARTH
DISCONNECT RECTIFICATION LEAD FROM ELECTRODE (LEFT ELECTRODE)
RESISTANCE FAN
REMOVE CONNECTOR FROM FAN
RESISTANCE SPARK GENERATOR
UNPLUG MAINS CONNECTION FROM UNDERNEATH SPARK GENERATOR
RESISTANCE RECTIFICATION LEAD
{GAINPCBACS}
DISCONNECT RECTIFICATION LEAD FROM ELECTRODE ASSEMBLY
VOLTAGE CH DEMAND INTO BOARD
{GAINPCBACS}
INFORMATION OPTIONAL DIVERTER VALVE KIT ONLY
THIS FAULT CODE
VOLTAGE MAINS POWER IN
{GAINPCBACS}
RESISTANCE FUSE (MAINS FUSE)
REMOVE THE FUSE FROM THE FUSED SPUR
VOLTAGE FAN AT PCB
{GAINPCBACS}
REMOVE THE CONNECTOR FROM THE FAN ASSEMBLY AND MAKE SAFE
VOLTAGE FAN AT PCB
{GAINPCBACS}
REMOVE THE CONNECTOR FROM THE FAN ASSEMBLY AND MAKE SAFE
OBSERVATION BOILER RESET (OVERHEAT)
ENSURE BOILER IS COOL
RESISTANCE OVERHEAT STAT AND HARNESS
{GAINPCBACS}
DISCONNECT LV1 FROM THE PCB
RESISTANCE OVERHEAT STAT
DISCONNECT LEADS FROM OVERHEAT THERMOSTAT
RESISTANCE GAS VALVE AND HARNESS
{GAINPCBACS}
DISCONNECT LV1 FROM THE PCB
RESISTANCE GAS VALVE
DISCONNECT PLUG FROM GAS VALVE
RESISTANCE LOW LOSS HEADER SENSOR
REMOVE THE LOW LOSS HEADER SENSOR CONNECTOR FROM THE PCB (LIGHT GREEN)
OBSERVATION SPARKING AT ELECTRODE LEAD
WEDGE THE IGNITION LEAD BETWEEN THE 2 SPARK ELECTRODES AS SHOWN IN THE IMAGE
VOLTAGE SPARK GENERATOR AT PCB
{GAINPCBACS}
RESISTANCE HARNESS PCB TO SPARK GENERATOR
DISCONNECT THE BOTTOM CONNECTOR FROM SPARK GENERATOR
PRESSURE FAN IGNITION
ATTACH PRESSURE GAUGE TO FAN PRESSURE TEST POINT
PRESSURE GAS INLET AND DROP
ATTACH U-GAUGE TO IN
INSPECTION FAN BEARING PLATE
REMOVE FAN AND FAN BEARING PLATE (LOCATED ABOVE THE FAN)
INSPECTION BURNER ASSEMBLY
REMOVE THE BURNER ASSEMBLY FROM THE APPLIANCE
VOLTAGE GAS VALVE AT PCB
{GAINPCBACS}
RESISTANCE HARNESS GAS VALVE
REMOVE CONNECTOR FROM GAS VALVE
INSPECTION BURNER ASSEMBLY
REMOVE THE BURNER ASSEMBLY FROM THE APPLIANCE
RESISTANCE ELECTRODE GND PATH
REMOVE THE LEAD FROM THE MIDDLE ELECTRODE
OBSERVATION DOES PUMP RUN WITH DC CONNECTOR REMOVED?
REMOVE THE DC PUMP CONNECTOR
NO DEMAND
RESISTANCE HARNESS PUMP
DISCONNECT THE PLUG FROM THE PUMP
REMOVE SAFETY CLIP TO EXPOSE ELECTRICAL CONNECTORS
RESISTANCE HARNESS PUMP DC
REMOVE THE DC PUMP CONNECTOR FROM THE PUMP
VOLTAGE DC PUMP
REMOVE THE DC CONNECTOR FROM THE PUMP
ENSURE NO DEMAND
RESISTANCE HARNESS PUMP DC
REMOVE THE DC PUMP CONNECTOR FROM THE PUMP
VOLTAGE DC PUMP
REMOVE THE DC CONNECTOR FROM THE PUMP
ENSURE NO DEMAND
RESISTANCE HARNESS PUMP DC
REMOVE THE DC PUMP CONNECTOR FROM THE PUMP
RESISTANCE HARNESS PUMP
DISCONNECT THE PLUG FROM THE PUMP
REMOVE SAFETY CLIP TO EXPOSE ELECTRICAL CONNECTORS
VOLTAGE DC PUMP
REMOVE THE DC CONNECTOR FROM THE PUMP
ENSURE NO DEMAND
RESISTANCE HARNESS PUMP DC
REMOVE THE DC PUMP CONNECTOR FROM THE PUMP
RESISTANCE HARNESS PUMP
DISCONNECT THE PLUG FROM THE PUMP
REMOVE SAFETY CLIP TO EXPOSE ELECTRICAL CONNECTORS
VOLTAGE DC PUMP
REMOVE THE DC CONNECTOR FROM THE PUMP
ENSURE NO DEMAND
RESISTANCE HARNESS PRESSURE SENSOR
REMOVE CONNECTOR FROM PRESSURE SENSOR (BEHIND SIPHON, UNLOCK FOR ACCESS)
VOLTAGE PRESSURE SENSOR (PRESSURE)
{GAINPCBACS}
RESISTANCE FLOW THERMISTOR
DISCONNECT LEADS TO FLOW THERMISTOR
RESISTANCE HEATING BLOCK THERMISTOR
REMOVE CONNECTOR FROM THE HEATING BLOCK THERMISTOR
PRESSURE GAS INLET
ATTACH U-GAUGE TO IN
PRESSURE GAS INLET
ATTACH U-GAUGE TO IN
PRESSURE FAN IGNITION
ATTACH PRESSURE GAUGE TO FAN PRESSURE TEST POINT
INSPECTION FAN BEARING PLATE
REMOVE FAN AND FAN BEARING PLATE (LOCATED ABOVE THE FAN)
INSPECTION BURNER ASSEMBLY
REMOVE THE BURNER ASSEMBLY FROM THE APPLIANCE
VOLTAGE RECTIFICATION
{GAINPCBACS}
INSPECTION AIR INLET INTEGRITY
REFIT COMBUSTION CHA
PRESSURE GAS INLET (MAXIMUM RATE)
ATTACH U-GAUGE TO IN
FURTHER INVESTIGATION FLAME LOSS AFTER IGNITION
TESTS SO FAR HAVE FO
PRESSURE GAS INLET (MAXIMUM RATE)
ATTACH U-GAUGE TO IN
INSPECTION BURNER ASSEMBLY
REMOVE THE BURNER ASSEMBLY FROM THE APPLIANCE
INSPECTION HEAT EXCHANGER FLUEWAYS
REMOVE FLUEWAYS INSPECTION PLATE
PRESSURE GAS INLET (MAXIMUM RATE)
ATTACH U-GAUGE TO IN
INSPECTION BURNER ASSEMBLY
REMOVE THE BURNER ASSEMBLY FROM THE APPLIANCE
INSPECTION BURNER ASSEMBLY
REMOVE THE BURNER ASSEMBLY FROM THE APPLIANCE
INSPECTION HEAT EXCHANGER FLUEWAYS
REMOVE FLUEWAYS INSPECTION PLATE
INSPECTION HEAT EXCHANGER FLUEWAYS
REMOVE FLUEWAYS INSPECTION PLATE
RESISTANCE RECTIFICATION LEAD
{GAINPCBACS}
DISCONNECT RECTIFICATION LEAD FROM ELECTRODE ASSEMBLY
INSPECTION AIR INLET INTEGRITY
REFIT COMBUSTION CHA
RESISTANCE FAN AND HARNESS
REMOVE CONNECTOR HV2 FROM THE PCB
RESISTANCE SPARK GENERATOR AND HARNESS
DISCONNECT CONNECTOR HV2 FROM THE PCB
VOLTAGE FAN AT PCB
{GAINPCBACS}
REMOVE THE CONNECTOR FROM THE FAN ASSEMBLY AND MAKE SAFE
RESISTANCE HARNESS FAN
DISCONNECT FAN CONNECTOR FROM FAN
PRESSURE GAS INLET (MAXIMUM RATE)
ATTACH U-GAUGE TO IN
VOLTAGE RECTIFICATION
{GAINPCBACS}
RESISTANCE HEATING BLOCK THERMISTOR
REMOVE CONNECTOR FROM THE HEATING BLOCK THERMISTOR
RESISTANCE HEATING BLOCK THERMISTOR
REMOVE CONNECTOR FROM THE HEATING BLOCK THERMISTOR
VOLTAGE PRESSURE SENSOR (PRESSURE)
{GAINPCBACS}
RESISTANCE FLOW THERMISTOR (FAULT CODE)
DISCONNECT LEADS TO FLOW THERMISTOR
RESISTANCE FLOW THERMISTOR
DISCONNECT LEADS TO FLOW THERMISTOR
RESISTANCE HEATING BLOCK THERMISTOR
REMOVE CONNECTOR FROM THE HEATING BLOCK THERMISTOR
VOLTAGE MAINS POWER IN (LOW VOLTAGE)
{GAINPCBACS}
OBSERVATION EXTERNAL FROST THERMOSTAT FITTED?
GAIN ACCESS TO THE INCOMING CONNECTIONS AT THE PCB
VOLTAGE EXTERNAL FROST PROTECTION
GAIN ACCESS TO THE INCOMING CONNECTIONS AT THE PCB
RESISTANCE FLOW THERMISTOR
DISCONNECT LEADS TO FLOW THERMISTOR
RESISTANCE HEATING BLOCK THERMISTOR
REMOVE CONNECTOR FROM THE HEATING BLOCK THERMISTOR
RESISTANCE FLOW THERMISTOR
DISCONNECT LEADS TO FLOW THERMISTOR
RESISTANCE HEATING BLOCK THERMISTOR
REMOVE CONNECTOR FROM THE HEATING BLOCK THERMISTOR
OBSERVATION DISCONNECT 240V CONTROL DOES DEMAND END
DISCONNECT THE WIRING FROM THE 240V EXTERNAL CONTROLS AND MAKE SAFE
OBSERVATION DISCONNECT 240V CONTROL DOES DEMAND END
DISCONNECT THE WIRING FROM THE 240V EXTERNAL CONTROLS AND MAKE SAFE
TEMPERATURE LOW LOSS HEADER (FROST PROTECTION PUMP)
LOCATE THE LOW LOSS HEADER ON THE SYSTEM
(THIS MAY NOT BE NEXT TO THE APPLIANCE)
RESISTANCE LOW LOSS HEADER SENSOR
REMOVE THE LOW LOSS HEADER SENSOR CONNECTOR FROM THE PCB (LIGHT GREEN)
PRESSURE GAS INLET (MAXIMUM RATE - OUTPUT)
ATTACH U-GAUGE TO IN
PRESSURE FAN MAX RATE
ATTACH PRESSURE GAUGE TO FAN PRESSURE TEST POINT
INSPECTION FAN BEARING PLATE
REMOVE FAN AND FAN BEARING PLATE (LOCATED ABOVE THE FAN)
INSPECTION BURNER ASSEMBLY
REMOVE THE BURNER ASSEMBLY FROM THE APPLIANCE
RESISTANCE LOW LOSS HEADER SENSOR
REMOVE THE LOW LOSS HEADER SENSOR CONNECTOR FROM THE PCB (LIGHT GREEN)
DIFFERENTIAL PRIMARY HEAT EXCHANGER
ATTACH TEMPERATE CLAMP TO RETURN PIPE ABOVE PUMP AS SHOWN
OBSERVATION RUN TO MAX TEMP-OVERHEAT OCCUR
ATTACH TEMPERATURE PROBE TO PIPE AS INDICATED BY THE RED ARROW
RESISTANCE FUSE (PCB)
REMOVE THE FUSE FROM ITS HOUSING
OBSERVATION DISCONNECT LV2
DISCONNECT CONNECTOR LV2 FROM THE PCB (REFER TO PICTURE)
RESISTANCE HARNESS FAN
DISCONNECT FAN CONNECTOR FROM FAN
PRESSURE FAN IGNITION
ATTACH PRESSURE GAUGE TO FAN PRESSURE TEST POINT
INSPECTION FAN BEARING PLATE
REMOVE FAN AND FAN BEARING PLATE (LOCATED ABOVE THE FAN)
INSPECTION BURNER ASSEMBLY
REMOVE THE BURNER ASSEMBLY FROM THE APPLIANCE
RESISTANCE FLOW THERMISTOR
DISCONNECT LEADS TO FLOW THERMISTOR
PRESSURE EXPANSION VESSEL
PRIMARY HEATING WATER DRAINED AND DISCHARGED
RESISTANCE FLOW THERMISTOR
DISCONNECT LEADS TO FLOW THERMISTOR
INSPECTION AIR INLET INTEGRITY
REFIT COMBUSTION CHA
INSPECTION BURNER ASSEMBLY
REMOVE THE BURNER ASSEMBLY FROM THE APPLIANCE
INSPECTION HEAT EXCHANGER FLUEWAYS
REMOVE FLUEWAYS INSPECTION PLATE
RESISTANCE HARNESS FAN
DISCONNECT FAN CONNECTOR FROM FAN
OBSERVATION DOES PUMP RUN
NO DEMAND
INSPECTION BURNER ASSEMBLY
REMOVE THE BURNER ASSEMBLY FROM THE APPLIANCE
OBSERVATION DISCONNECT PRESSURE SENSOR
REMOVE CONNECTOR FROM THE PRESSURE SENSOR AND MAKE SAFE