Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Gain access to PCB (use Insulation Mat as required)
Disconnect LV1 from the PCB
Disconnect LV1 from the PCB
Measurement:
Measure the resistance between the pin 11 (red) to pin 13 (red) at connector LV1.
Resistance should be short circuit (zero resistance).
Is the resistance measured as expected?
Note:
Connector may differ slightly in appearance but this does not affect the test.
Resistance should be short circuit (zero resistance).
Is the resistance measured as expected?
Note:
Connector may differ slightly in appearance but this does not affect the test.

Isolate as per TOPs P4
and refit as necessary