XSol Diagnostic System

Interactive Test Sequence Navigator

Welcome to the XSol Diagnostic System

This system provides interactive diagnostic tests with proper sequence navigation based on the decoded .seq file logic.

Start Diagnostic Sequence

or choose a specific test below:

WORCESTER GREENSTAR RI ERP +

GLOBALLY REPLACED

Next: &1, *

NO FAULT FOUND

Next: nff

POWER UP

Next: &2613, f4

OBSERVATION BURNER IGNITES AND ESTABLISHES

ENSURE THE APPLIANCE IS COOL (BELOW 40°C)
BOILER THERMOSTAT SET TO MAX

Next: &1440, ?67, ?424, ?838, ?1737

CH OPERATION

Next: &2186, ?203, ?205, ?207

OVERRUNS

Next: &1131, ?1764, ?1766

FAULT CODES

Next: &nff, !f797

COMBUSTION SETTINGS HIGH AND LOW

Next: &82, ?1468, ?1472

INSPECTION CONDENSATE TRAP OPERATION

UNSCREW CONTROL PANEL AND HOOK ON LOWER HOOKS SO CONDENSATE TRAP IS VISIBLE

Next: &nff, !f1132

PRESSURE FAN MAXIMUM

{GAINPCBACS}
CONNECT A PRESSURE GAUGE TO THE FAN PRESSURE TEST POINT

Next: &1439, f1871

PRESSURE GAS INLET MAX

ATTACH PRESSURE GAUGE TO THE INLET PRESSURE TEST POINT

Next: &920, !f1448

OBSERVATION PUMP RUNS

Next: &1438, f1449

FURTHER INVESTIGATION FUSE BLOWN (PCB FUSES)

OUTSIDE MODEL

Next: &nff, f1997

FURTHER INVESTIGATION FUSE BLOWN (MAINS FUSE)

OUTSIDE MODEL

Next: &nff, f2052

OPERATION DHW

Next: &84, ?2187, ?2189

FAULT CODE FAST FLASH (VOLATILE LOCK OUT)

OUTSIDE MODEL

Next: &nff, f2227

OBSERVATION FAN RUNS

ENSURE THE APPLIANCE IS COOL (BELOW 40°C)
BOILER THERMOSTAT SET TO MAX

Next: &62, f2614

INFORMATION FAN DEMAND VOLTAGE

THE PWM OR (DEMAND/S

Next: &nff, !f2811

LITE DIAGNOSTIC

DIAGNOSIS RELIES ON

Next: &nff, !f2902

QUICK ACCESS DATA AND INFORMATION

THE TABLE BELOW SHOW

Next: &nff, !f2904

HEADER FOR QADAI PRIMARY THERMISTOR

INTENTIONALLY BLANK - HEADER FOR QADAI

Next: &nff, f2906

HEADER FOR QADAI GAS VALVE RESISTANCE SIT

INTENTIONALLY BLANK - HEADER FOR QADAI

Next: &nff, f2910

HEADER FOR QADAI GAS VALVE VOLTAGE

INTENTIONALLY BLANK - HEADER FOR QADAI

Next: &nff, f2914

HEADER FOR QADAI PUMP VOLTAGE

INTENTIONALLY BLANK - HEADER FOR QADAI

Next: &nff, f2918

BURNER DOES NOT EST

ELECTRODE ASSEMBLY

Next: End

CALIBRATION LOW BOILER DOES NOT RAMP UP

SENSOR - PRIMARY (CONTROL)

Next: End

NOT DUMPING

SIPHON

Next: End

BURNER DOES NOT IGNITE PRESSURE DROPS

GAS VALVE INLET PRESSURE

Next: End

LOW

GAS VALVE INLET PRESSURE

Next: End

NO POWER TO PUMP

PCB

Next: End

BREACHED GASES MIXING

FLUE

Next: End

BLOCKED OR SPLIT BAFFLING

GAS SUPPLY TUBE

Next: End

BURNER IGNITES

HARNESS - MAINS

Next: End

BLOCKED OR SPLIT NO INLET DROP

GAS SUPPLY TUBE

Next: End

BLOCKED OR SPLIT DOES NOT ESTABLISH

GAS SUPPLY TUBE

Next: End

BLOCKED OR SPLIT DROPS ON MINIMUM

GAS SUPPLY TUBE

Next: End

BLOCKED OR SPLIT COMB SETTINGS INCORRECT

GAS SUPPLY TUBE

Next: End

OVERHEAT INVESTIGATION

FLUE

Next: End

OVERHEAT

SYSTEM PRESSURE

Next: End

OVERHEAT RUNNING SLOW

PUMP

Next: End

OVERHEAT

Next: End

OVERHEAT

SENSOR - PRIMARY (CONTROL)

Next: End

OVERHEAT

SYSTEM RESTRICTION OR BLOCKAGE

Next: End

COMBUSTION INCORRECT

FLUE / BURNER SEALS

Next: End

COMBUSTION INCORRECT 2

FLUE / BURNER SEALS

Next: End

COMBUSTION FAIL

FLUE

Next: End

BLOCKED OR SPLIT LOW FAN PRESSURE

GAS SUPPLY TUBE

Next: End

LOW FAN PRESSURE MAXIMUM

BURNER

Next: End

FAN PRESSURE

SIPHON

Next: End

OVERHEAT

FLUE / BURNER SEALS

Next: End

BURNERIGNITES

HARNESS - MAINS

Next: End

RECTIFICATION VOLTAGE

PCB

Next: End

UNSATISFACTORY CHECKS

Z BLANKS

Next: End

NOT ESTABLISHING

SIPHON

Next: End

FAILING FGA

SIPHON

Next: End

DROPS OUT IN MINIMUM

SIPHON

Next: End

CH OPERATION - NOISY

SYSTEM PRESSURE

Next: End

CH OPERATION - UP TO TEMP RADS COLD

SYSTEM PRESSURE

Next: End

FAN DOES NOT RUNFAULT CODE

CODE PLUG

Next: End

FAN DOES NOT RUN 1FAULT CODE

SENSOR - PRIMARY (CONTROL)

Next: End

BLOWN STAND BY MODE

FUSE (FUSED SPUR)

Next: End

DOES NOT ESTABLISH

BURNER

Next: End

FAN RUNS

AIR PRESSURE SWITCH

Next: End

FAN RUNS

LIMITER 120DEG C - TEMPERATURE

Next: End

FAN RUNS

TEMPERATURE LIMITER ASSEMBLY - PUSH FIT

Next: End

NOT IGNITING

SIPHON

Next: End

FAN RUNS - HIGH RESIST

AIR PRESSURE SWITCH

Next: End

FAN RUNS - HIGH RESIST

LIMITER 120DEG C - TEMPERATURE

Next: End

FAN RUNS - HIGH RESIST

TEMPERATURE LIMITER ASSEMBLY - PUSH FIT

Next: End

BURNER IGNITES

LEAD- IGNITION

Next: End

BURNER DOES NOT IGNITE

GAS SUPPLY TUBE

Next: End

BURNER IGNITES

ELECTRODE ASSEMBLY

Next: End

DOES NOT IGNITE

HEAT EXCHANGER PRIMARY FLUE WAYS

Next: End

DHW BURNER IGNITION ESTABLISH - INTERMITTENT

GAS VALVE INLET PRESSURE

Next: End

DHW BURNER IGNITION ESTABLISH - INTERMITTENT- HIGH RESIST

TEMPERATURE LIMITER ASSEMBLY - PUSH FIT (CORROSION)

Next: End

DHW BURNER IGNITION ESTABLISH - INTERMITTENT

ELECTRODE ASSEMBLY

Next: End

INTERMITTENT IGNITION COMBUSTION INCORRECT

FLUE / BURNER SEALS

Next: End

INTERMITTENT IGNITIONCOMBUSTION INCORRECT 2

FLUE / BURNER SEALS

Next: End

FAULT CODE OVERHEAT WILL NOT RESET

AIR PRESSURE SWITCH

Next: End

FAULT CODE OVERHEAT WILL NOT RESET

LIMITER 120DEG C - TEMPERATURE

Next: End

FAULT CODE OVERHEAT WILL NOT RESET

TEMPERATURE LIMITER ASSEMBLY - PUSH FIT

Next: End

OVERHEAT TRIPPING EARLY

LIMITER 120DEG C - TEMPERATURE

Next: End

240V SUPPLY

Next: End

BAFFLING

FLUE

Next: End

LOW FAN PRESSURE BAFFLING

BURNER

Next: End

FURTHER INVESTIGATION MAINS FUSE

GAS VALVE

Next: End

FURTHER INVESTIGATION

GAS VALVE

Next: End

FAN RUNS - NEW STYLE FAN

CABLE FAN CONNECTOR ASSEMBLY

Next: End

FAN DOES NOT RUN - NEW STYLE FAN

CODE PLUG

Next: End

FAN RUNS - NEW STYLE FAN

SENSOR - PRIMARY (CONTROL)

Next: End

FAN DOES NOT RUN FAN VOLTAGE OK - NEW STYLE FAN

CABLE FAN CONNECTOR ASSEMBLY

Next: End

BETWEEN 125 VAC AND 135 VAC - NEW STYLE

CABLE FAN CONNECTOR ASSEMBLY

Next: End

ABOVE 135 VAC - NEW STYLE

CABLE FAN CONNECTOR ASSEMBLY

Next: End

STSLOW THEN TO TO HIGH SPEED - NEW STYLE

CABLE FAN CONNECTOR ASSEMBLY

Next: End

VOLATILE LOCKOUT BETWEEN 125 VAC AND 135 VAC - NEW STYLE

CABLE FAN CONNECTOR ASSEMBLY

Next: End

VOLATILE LOCKOUT ABOVE 135 VAC - NEW STYLE

CABLE FAN CONNECTOR ASSEMBLY

Next: End

VOLATILE LOCKOUT STSLOW THEN TO TO HIGH SPEED - NEW STYLE

CABLE FAN CONNECTOR ASSEMBLY

Next: End

VOLATILE LOCKOUT FAN RUNS 1 - NEW STYLE

CABLE FAN CONNECTOR ASSEMBLY

Next: End

VOLATILE LOCKOUT FAN RUNS - NEW STYLE

CABLE FAN CONNECTOR ASSEMBLY

Next: End

BLANK DISPLAY

CABLE FAN CONNECTOR ASSEMBLY

Next: End

BLANK FOR LITE DIAGNOSTIC

Z BLANKS

Next: End

BLANK FOR QADAI

Z BLANKS

Next: End

QADAI

SENSOR - PRIMARY (CONTROL)

Next: End

QADAI SIT

GAS VALVE

Next: End

QADAI VOLTAGE TO PUMP

PCB

Next: End

FAN RUNS LOW BOILER GOES TO OVERHEAT BOILER NOISEY

SENSOR - PRIMARY (CONTROL)

Next: End

CH OPERATION

Next: End

BOILER TO TEMP RADS COOL

PUMP

Next: End

FOR TYPE DIAG PROCEDURE

Z BLANKS

Next: End

BLOWN STANDBY MODE

FUSE MAIN PCB F1

Next: End

POWER UP FAN RUNS

Next: End

NOISE BOILER

SIPHON

Next: End

FAULT CODE

Z BLANKS

Next: End

BURNER BAFFLING OUT

SIPHON

Next: End

BURNER BAFFLING OUT

GAS VALVE INLET PRESSURE

Next: End

FOR LED FURTHER INVESTIGATION

Z BLANKS

Next: End

BURNER IGNITES BUT DOES NOT ESTABLISH

GAS VALVE INLET PRESSURE

Next: End

CH OPERATION

Next: End

PUMP

PUMP

Next: End

PUMP WIRING

PUMP WIRING

Next: End

UNABLE TO SET

GAS VALVE

Next: End

SUPPLY FAULT

Next: End

BURNER IGNITES

GAS VALVE

Next: End

NO POWER TO GAS VALVE

PCB

Next: End

OVERRUN FUNCTION

PCB

Next: End

OVERRUN FIRES WITH NO DEMAND

CAPACITOR

Next: End

OVERHEAT NOT RUNNING

PUMP

Next: End

OVERHEAT

PUMP WIRING

Next: End

OVERHEAT

PCB

Next: End

DROPPING OUT ON MINIMUM

GAS VALVE

Next: End

BURNER DOES NOT IGNITE PRESSURE DROPS MAXIMUM

HEAT EXCHANGER PRIMARY FLUE WAYS

Next: End

FUSE MAINS

Z BLANKS

Next: End

OVERHEAT NO FAULT FOUND

NORMAL OPERATION

Next: End

BAFFLING

GAS VALVE BASE SETTINGS

Next: End

BOILER DOES NOT RAMP UP

PCB

Next: End

FAN DOES NOT RUNFAULT CODE

HARNESS - MAINS

Next: End

NO PRESSURE BAFFLING

FAN MEMBRANE

Next: End

BAFFLING - PRESSURE OK

FAN

Next: End

BURNER DOES NOT IGNITE

FAN MEMBRANE

Next: End

BURNER DOES NOT IGNITE

FAN

Next: End

BURNER DOES NOT EST

HEAT EXCHANGER PRIMARY FLUE WAYS

Next: End

SAFETY CIRCUIT

HARNESS - MAINS

Next: End

SAFETY CIRCUIT - HIGH RESIST

HARNESS - MAINS

Next: End

FAN RUNS BURNER DOES NOT IGNITE

FAN MEMBRANE

Next: End

FAN RUNS BURNER DOES NOT IGNITE

HEAT EXCHANGER PRIMARY FLUE WAYS

Next: End

NOT IGNITING WITH DROP

FAN MEMBRANE

Next: End

NOT IGNITING WITH DROP

FAN

Next: End

BURNER DOES NOT IGNITE

GAS VALVE

Next: End

DHW BURNER IGNITION ESTABLISH - INTERMITTENT 2

HEAT EXCHANGER PRIMARY FLUE WAYS

Next: End

DHW BURNER IGNITION ESTABLISH - INTERMITTENT

NO FAULT INTERMITTENT IGNITION

Next: End

FAN RUNS BURNER DOES NOT IGNITE - NO PRESSURE DROP

TEMPERATURE LIMITER ASSEMBLY - PUSH FIT (CORROSION)

Next: End

FAN RUNS BURNER DOES NOT IGNITE - NO SPARKING

TEMPERATURE LIMITER ASSEMBLY - PUSH FIT (CORROSION)

Next: End

OVERHEAT INVESTIGATION

TEMPERATURE LIMITER ASSEMBLY - PUSH FIT (CORROSION)

Next: End

FAULT CODE OVERHEAT

HARNESS - MAINS

Next: End

PRESSURE FAN MAXIMUM

FAN MEMBRANE

Next: End

PRESSURE FAN MAXIMUM

FAN

Next: End

OPERATION DHW

Next: End

WRONG MIX BAFFLING

GAS VALVE

Next: End

OVERHEAT TRIPPING EARLY

TEMPERATURE LIMITER ASSEMBLY - PUSH FIT

Next: End

CH NOISY

SYSTEM RESTRICTION OR BLOCKAGE

Next: End

BAFFLES - LOW PRESSURE

FAN MEMBRANE

Next: End

BURNER DOES NOT IGNITE PRESSURE DROPS BAFFLING

HEAT EXCHANGER PRIMARY FLUE WAYS

Next: End

FURTHER INVESTIGATION FUSE F1 FURTHER INVESTIGATION

CABLE FAN CONNECTOR ASSEMBLY

Next: End

FURTHER INVESTIGATION FURTHER INVESTIGATION

PCB (FUSE INVESTIGATION)

Next: End

FUSE FURTHER INVESTIGATION 2

MAINS FUSE BLOWN - FURTHER INVESTIGATION

Next: End

FAN RUNS - NEW STYLE FAN

HARNESS - MAINS

Next: End

STANDBY

PCB

Next: End

BLANK DISPLAY

FAN

Next: End

PRIMARY THERMISTOR

RESULT AS EXPECTED

Next: End

GAS VALVE RESISTANCE SIT

RESULT AS EXPECTED

Next: End

PCB VOLTAGE TO GAS VALVE

RESULT AS EXPECTED

Next: End

PCB VOLTAGE TO PUMP

RESULT AS EXPECTED

Next: End

LED

PCB

Next: End

FUSE F1 APPLIANCE

Z BLANKS

Next: End

COMBUSTION SETTINGS INCORRECT

CHARACTERISTIC TEST FROM COMBUSTION SETTINGS HIGH AND LOW

Next: p2089

BURNER DROPS OUT IN MINIMUM OUTPUT MODE

CHARACTERISTIC TEST FROM COMBUSTION SETTINGS HIGH AND LOW

Next: p2097

BURNER DOES NOT IGNITE SMOOTHLY / INTERMITTENT IGNITION

CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITES AND ESTABLISHES

Next: p2501

FAN / PUMP DO NOT OVERRUN AS ABOVE

CHARACTERISTIC TEST FROM OVERRUNS

Next: !p1765

MAINS VOLTAGE PRESENT

CHARACTERISTIC TEST FROM VOLTAGE BOILER SWITCHED LIVE (NO DEMAND)

Next: !p1771

VOLTAGE PRESENT BUT LOW (APPROX 60-100V)

CHARACTERISTIC TEST FROM VOLTAGE BOILER SWITCHED LIVE (NO DEMAND)

Next: !p1773

TEMPERATURE ABOVE 90°C AND BOILER STILL FIRED

CHARACTERISTIC TEST FROM OBSERVATION RUN BOILER TO MAX TEMP - DOES OVERHEAT OCCUR

Next: !p1843

BOILER RETURNS TO FAULT CODE, TEMPERATURE 90°C OR BELOW

CHARACTERISTIC TEST FROM OBSERVATION RUN BOILER TO MAX TEMP - DOES OVERHEAT OCCUR

Next: p2610

BOILER NOISY DURING OPERATION

CHARACTERISTIC TEST FROM CH OPERATION

Next: p2197

BOILER REACHES TEMPERATURE, RADS DO NOT HEAT OR ONLY GET WARM

CHARACTERISTIC TEST FROM CH OPERATION

Next: p2214

BOILER CONTINUES TO FIRE BUT RADIATORS ONLY GET WARM

CHARACTERISTIC TEST FROM CH OPERATION

Next: p1101

BOILER DOES NOT RESPOND TO DHW DEMAND

CHARACTERISTIC TEST FROM OPERATION DHW

Next: !p2605

DHW OPERATION UNSATISFACTORY

CHARACTERISTIC TEST FROM OPERATION DHW

Next: !p2190

FAST FLASH (VOLATILE LOCKOUT) DISPLAYED WITHIN 10 SECONDS

CHARACTERISTIC TEST FROM OBSERVATION BLUE LED - FAULT CODE

Next: p2230

FAST FLASH (VOLATILE LOCKOUT) DISPLAYED AFTER MORE THAN 20 SECONDS, FAN DOES NOT RUN

CHARACTERISTIC TEST FROM OBSERVATION BLUE LED - FAULT CODE

Next: p2882

FAN MEMBRANE DAMAGED OR WORN

CHARACTERISTIC TEST FROM INSPECTION FAN MEMBRANE

Next: !p2313

FAN STIFF TO TURN OR SEIZED

CHARACTERISTIC TEST FROM INSPECTION FAN MEMBRANE

Next: !p2315

FAN MEMBRANE DAMAGED OR WORN

CHARACTERISTIC TEST FROM INSPECTION FAN MEMBRANE

Next: !p2334

FAN STIFF TO TURN OR SEIZED

CHARACTERISTIC TEST FROM INSPECTION FAN MEMBRANE

Next: !p2336

FLUE STAT CORRODED, DAMAGED, OR MOISTURE PRESENT

CHARACTERISTIC TEST FROM RESISTANCE SAFETY CIRCUIT

Next: !p2569

RESISTANCE NOT AS EXPECTED

CHARACTERISTIC TEST FROM RESISTANCE SAFETY CIRCUIT

Next: p2393

FLUE STAT CORRODED, DAMAGED, OR MOISTURE PRESENT

CHARACTERISTIC TEST FROM RESISTANCE SAFETY CIRCUIT

Next: !p2568

RESISTANCE NOT AS EXPECTED

CHARACTERISTIC TEST FROM RESISTANCE SAFETY CIRCUIT

Next: p2459

FAN MEMBRANE DAMAGED OR WORN

CHARACTERISTIC TEST FROM INSPECTION FAN MEMBRANE

Next: !p2472

FAN STIFF TO TURN OR SEIZED

CHARACTERISTIC TEST FROM INSPECTION FAN MEMBRANE

Next: !p2474

FAN MEMBRANE DAMAGED OR WORN

CHARACTERISTIC TEST FROM INSPECTION FAN MEMBRANE

Next: !p2486

FAN STIFF TO TURN OR SEIZED

CHARACTERISTIC TEST FROM INSPECTION FAN MEMBRANE

Next: !p2488

FAN MEMBRANE DAMAGED OR WORN

CHARACTERISTIC TEST FROM INSPECTION FAN MEMBRANE

Next: !p2513

FAN STIFF TO TURN OR SEIZED

CHARACTERISTIC TEST FROM INSPECTION FAN MEMBRANE

Next: !p2515

BURNER DROPS OUT IN MINIMUM MODE

CHARACTERISTIC TEST FROM INSPECTION FAN MEMBRANE

Next: p2559

CO2 SETTINGS INCORRECT

CHARACTERISTIC TEST FROM INSPECTION FAN MEMBRANE

Next: p2550

FAN MEMBRANE DAMAGED OR WORN

CHARACTERISTIC TEST FROM INSPECTION FAN MEMBRANE

Next: !p2547

FAN STIFF TO TURN OR SEIZED

CHARACTERISTIC TEST FROM INSPECTION FAN MEMBRANE

Next: !p2549

FLUE STAT CORRODED, DAMAGED, OR MOISTURE PRESENT

CHARACTERISTIC TEST FROM RESISTANCE SAFETY CIRCUIT

Next: !p2571

RESISTANCE NOT AS EXPECTED

CHARACTERISTIC TEST FROM RESISTANCE SAFETY CIRCUIT

Next: p2574

FAN MEMBRANE DAMAGED OR WORN

CHARACTERISTIC TEST FROM INSPECTION FAN MEMBRANE

Next: !p2602

FAN STIFF TO TURN OR SEIZED

CHARACTERISTIC TEST FROM INSPECTION FAN MEMBRANE

Next: !p2604

FAN MEMBRANE DAMAGED OR WORN

CHARACTERISTIC TEST FROM INSPECTION FAN MEMBRANE

Next: !p2731

FAN STIFF TO TURN OR SEIZED

CHARACTERISTIC TEST FROM INSPECTION FAN MEMBRANE

Next: !p2733

240 VOLTS ACROSS PURPLE BROWN OTHERS NOT AS ABOVE

CHARACTERISTIC TEST FROM VOLTAGE FAN (AT PCB) - NEW STYLE

Next: p2831

240 VOLTS ACROSS PURPLE/BROWN ABSENT

CHARACTERISTIC TEST FROM VOLTAGE FAN (AT PCB) - NEW STYLE

Next: !p2833

VOLTAGE ABOVE 120 VAC

CHARACTERISTIC TEST FROM FAN VOLTAGE CONTROL (PCB) - NEW STYLE

Next: p2852

VOLTAGE BETWEEN 110 VAC AND 120 VAC

CHARACTERISTIC TEST FROM FAN VOLTAGE CONTROL (PCB) - NEW STYLE

Next: p2854

VOLTAGE ABOVE 120 VAC

CHARACTERISTIC TEST FROM FAN VOLTAGE CONTROL (PCB) - NEW STYLE

Next: p2873

VOLTAGE BETWEEN 110 VAC AND 120 VAC

CHARACTERISTIC TEST FROM FAN VOLTAGE CONTROL (PCB) - NEW STYLE

Next: p2875

240 VOLTS ABSENT BETWEEN PURPLE/BROWN

CHARACTERISTIC TEST FROM FAN VOLTAGE CONTROL (PCB) - NEW STYLE

Next: !p2885

240 VOLTS PRESENT BETWEEN PURPLE/BROWN BUT OTHERS NOT AS ABOVE

CHARACTERISTIC TEST FROM FAN VOLTAGE CONTROL (PCB) - NEW STYLE

Next: p2887

BURNER DOES NOT IGNITE

CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITES AND ESTABLISHES

Next: p1135

BURNER IGNITES SMOOTHLY, BUT DOES NOT ESTABLISH

CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITES AND ESTABLISHES

Next: p888

BURNER IGNITES BUT IS NOISY AND/OR BAFFLES OUT

CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITES AND ESTABLISHES

Next: p839

VOLTAGE PUMP

REMOVE COVER FROM PUMP ASSEMBLY

Next: !p1450, f1451

VOLTAGE PUMP AT PCB

{GAINPCBACS}

Next: !p1452, !f1453

RESISTANCE SAFETY CIRCUIT

DISCONNECT CONNECTOR FROM ST9 ON THE PCB

Next: p1610, ?2456, ?2458

RESISTANCE MAINS FUSE

REMOVE FUSE FROM FUSED SPUR

Next: !p16, f18

RESISTANCE GAS VALVE HARNESS

REMOVE THE CONNECTOR

Next: !p1629, !f1630

OBSERVATION BOILER RESET OVERHEAT FAULT

ENSURE APPLIANCE IS COOL

Next: p1794, f1795

RESISTANCE SAFETY CIRCUIT

DISCONNECT CONNECTOR FROM ST9 ON THE PCB

Next: p1796, ?2570, ?2572

VOLTAGE PUMP

REMOVE COVER FROM PUMP ASSEMBLY

Next: !p1810, f1811

VOLTAGE PUMP AT PCB

{GAINPCBACS}

Next: !p1812, !f1813

CONDENSATE

Next: p2584, !f1881

INSPECTION FAN MEMBRANE

REMOVE AIR/GAS FAN ASSEMBLY

Next: !p2607, ?2312, ?2314

RESISTANCE - SIT GAS VALVE AND HARNESS - FURTHER INVESTIGATION

REMOVE ST9 CONNECTOR FROM THE PCB

Next: p2760, f2781

RESISTANCE - SIT GAS VALVE AND HARNESS - FURTHER INVESTIGATION

REMOVE ST9 CONNECTOR FROM THE PCB

Next: p2736, f2757

OBSERVATION BLUE LED - FAULT CODE

ON / OFF SWITCH TURNED TO OFF

Next: p2870, ?2229, ?2231

RESISTANCE SENSOR TEMP FLOW

DISCONNECT PLUG (RE

Next: !p2268, !f2269

INSPECTION FLUE

Next: p2329, !f2330

RESISTANCE SAFETY CIRCUIT

DISCONNECT CONNECTOR FROM ST9 ON THE PCB

Next: p2849, ?2389, ?2391

INSPECTION FLUE

Next: p2467, !f2468

CONDENSATE

Next: p2504, !f2505

VOLTAGE BOILER SWITCHED LIVE

{GAINPCBACS}

Next: p2828, !f2616

INSPECTION FAN MEMBRANE

REMOVE AIR/GAS FAN ASSEMBLY

Next: p2729, ?2730, ?2732

RESISTANCE PUMP

REMOVE COVER FROM PUMP ASSEMBLY
DISCONNECT WIRES FROM PUMP

Next: !p2739, !f2740

RESISTANCE FAN

DISCONNECT FAN CONNECTOR AT FAN

Next: !p2743, !f2868

RESISTANCE - SIT GAS VALVE SOLENOIDS

REMOVE THE TWO CONNECTORS FROM THE GAS VALVE

Next: !p2758, !f2759

RESISTANCE PUMP

REMOVE COVER FROM PUMP ASSEMBLY
DISCONNECT WIRES FROM PUMP

Next: !p2763, !f2764

RESISTANCE FAN

DISCONNECT FAN CONNECTOR AT FAN

Next: !p2767, !f2864

RESISTANCE - SIT GAS VALVE SOLENOIDS

REMOVE THE TWO CONNECTORS FROM THE GAS VALVE

Next: !p2782, !f2783

RESISTANCE SENSOR TEMP FLOW

DISCONNECT PLUG (RE

Next: !p2842, !f2843

RESISTANCE FAN HARNESS

DISCONNECT THE FAN CONNECTOR FROM THE PCB
DISCONNECT THE FAN CONNECTOR FROM THE FAN ASSEMBLY

Next: !p2899, !f2900

RESISTANCE SENSOR TEMP FLOW AND HARNESS

DISCONNECT CONNECTOR FROM ST9 ON THE PCB

Next: !p2907, !f2908

RESISTANCE - SIT GAS VALVE AND HARNESS - FURTHER INVESTIGATION

REMOVE ST9 CONNECTOR FROM THE PCB

Next: !p2911, !f2912

VOLTAGE GAS VALVE

DISCONNECT CONNECTOR

Next: !p2915, !f2916

VOLTAGE PUMP AT PCB

{GAINPCBACS}

Next: !p2919, !f2920

MAINS POWER INPUT TO APPLIANCE

{GAINPCBACS}

Next: p488, f15

VOLTAGE BOILER SWITCHED LIVE

{GAINPCBACS}

Next: p570, !f581

FUSE FURTHER INVESTIGATION (F1)

Next: !p573, !f574

ELECTRODE SENSE HARNESS

DISCONNECT FLAME SENSE LEAD FROM ELECTRODE
DISCONNECT CONNECTOR ST9 FROM THE PCB

Next: p1987, !f1955

INSPECTION FLUE

Next: p1082, !f1083

ELECTRODE SENSE

REMOVE THE ELECTRODE ASSEMBLY

Next: !p1084, !f1085

BYPASS SYSTEM

Next: p1104, !f1105

RESISTANCE SENSOR TEMP FLOW

DISCONNECT PLUG (RE

Next: !p2222, !f1107

SPARKING PRESENT TEST

{GAINPCBACS}
REMO

Next: p2400, f2339

GAS INLET PRESSURE

ATTACH PRESSURE GAUGE TO THE INLET PRESSURE TEST POINT

Next: p1252, !f1253

PRESSURE GAS INLET DROP

ATTACH U GAUGE TO INLET PRESSURE TEST POINT
ON/OFF SWITCH ON

Next: p2478, f1495

INSPECTION FLUE

Next: !p1475, !f1476

INSPECTION GAS SUPPLY TUBE

Next: p2703, !f1593

FAN PRESSURE-BAFFLING

ATTACH PRESSURE GAUGE TO FAN PRESSURE TEST POINT

Next: p1934, f2728

INSPECTION GAS SUPPLY TUBE

Next: p1613, !f1689

PRESSURE FAN - IGNITION

ATTACH A PRESSURE GAUGE TO THE FAN PRESSURE TEST POINT
ON/OFF SWITCH ON

Next: p1614, f2466

VOLTAGE GAS VALVE

DISCONNECT CONNECTOR

Next: !p1627, f1628

INSPECTION GAS SUPPLY TUBE

Next: p2316, !f1712

INSPECTION GAS SUPPLY TUBE

Next: p1857, !f1736

INSPECTION GAS SUPPLY TUBE

Next: p1865, !f1735

VOLTAGE BOILER SWITCHED LIVE (NO DEMAND)

{GAINPCBACS}

Next: !p1768, ?1770, ?1772

INSPECTION FLUE

Next: !p1804, !f1805

OBSERVATION PUMP RUNS

Next: p1808, f1809

PUMP LIMPET TEST

Next: p1814, !f1815

BYPASS SYSTEM

Next: p1816, !f1817

RESISTANCE SENSOR TEMP FLOW

DISCONNECT PLUG (RE

Next: p1882, !f1819

MEASURE HEAT EXCHANGER TEMPERATURE DIFFERENCE

UNSCREW CONTROL BOX

Next: p1840, !f1821

OBSERVATION RUN BOILER TO MAX TEMP - DOES OVERHEAT OCCUR

ATTACH TEMPERATURE CLAMP TO FLOW PIPE
SET BOILER TEMPERATURE CONTROL TO MAX

Next: !p1904, ?1842, ?1844

INSPECTION SEAL INTEGRITY

Next: p1474, !f1861

INSPECTION FLUE

Next: !p1863, !f1870

INSPECTION SEAL INTEGRITY

Next: p1862, !f1869

INSPECTION GAS SUPPLY TUBE

Next: p2596, !f1874

INSPECTION BURNER

REMOVE FAN
REMOVE THE BURNER

Next: !p1875, !f1876

INSPECTION SEAL INTEGRITY

Next: p1818, !f1902

RECTIFICATION VOLTAGE

DISCONNECT FLAME SENSE LEAD (GREEN LEAD) FROM SENSE ELECTRODE AND SECURE IT AS SHOWN

Next: p1078, !f1995

CONDENSATE

Next: p1700, !f2050

PUMP LIMPET TEST

Next: p332, !f353

CONDENSATE

Next: p1729, !f2105

CONDENSATE

Next: p1733, !f2106

KEYED PLUG

LOWER THE FACIA PANEL

Next: p2264, !f2265

RESISTANCE SENSOR TEMP FLOW AND HARNESS

DISCONNECT CONNECTOR FROM ST9 ON THE PCB

Next: !p2266, f2267

PRESSURE FAN - IGNITION

ATTACH A PRESSURE GAUGE TO THE FAN PRESSURE TEST POINT
ON/OFF SWITCH ON

Next: p1077, f2328

INSPECTION FAN MEMBRANE

REMOVE AIR/GAS FAN ASSEMBLY

Next: p2331, ?2333, ?2335

INSPECTION BURNER

REMOVE FAN
REMOVE THE BURNER

Next: !p2337, !f2338

RESISTANCE APS

DISCONNECT ONE OF THE ORANGE LEADS FROM THE AIR PRESSURE SWITCH

Next: p2394, !f2395

RESISTANCE OH STAT

DISCONNECT ONE OF THE ORANGE LEADS FROM THE OVERHEAT STAT

Next: p2396, !f2397

RESISTANCE FLUE OVERHEAT STAT

DISCONNECT ONE OF THE ORANGE LEADS FROM THE FLUE OVERHEAT STAT

Next: !p2398, !f2399

CONDENSATE

Next: p1251, !f2455

RESISTANCE APS

DISCONNECT ONE OF THE ORANGE LEADS FROM THE AIR PRESSURE SWITCH

Next: p2460, !f2461

RESISTANCE OH STAT

DISCONNECT ONE OF THE ORANGE LEADS FROM THE OVERHEAT STAT

Next: p2462, !f2463

RESISTANCE FLUE OVERHEAT STAT

DISCONNECT ONE OF THE ORANGE LEADS FROM THE FLUE OVERHEAT STAT

Next: !p2464, !f2465

INSPECTION FAN MEMBRANE

REMOVE AIR/GAS FAN ASSEMBLY

Next: p2469, ?2471, ?2473

INSPECTION BURNER

REMOVE FAN
REMOVE THE BURNER

Next: !p2475, !f2476

ELECTRODE SPARK HARNESS

REMOVE THE IGNITION HARNESS CONNECTION FROM THE ELECTRODES TOP OF THE BURNER AND FROM THE PCB

Next: p2479, !f2480

INSPECTION GAS SUPPLY TUBE

Next: p2481, !f2482

INSPECTION FAN MEMBRANE

REMOVE AIR/GAS FAN ASSEMBLY

Next: p2483, ?2485, ?2487

INSPECTION IGNITION ELECTRODE

REMOVE THE ELECTRODE ASSEMBLY

Next: p2489, !f2490

INSPECTION BURNER

REMOVE FAN
REMOVE THE BURNER

Next: p2491, !f2492

FLUEWAYS PRIMARY HEAT EXCHANGER

Next: !p2493, !f2494

PRESSURE FAN MAXIMUM

{GAINPCBACS}
CONNECT A PRESSURE GAUGE TO THE FAN PRESSURE TEST POINT

Next: p2502, f2503

GAS INLET PRESSURE

ATTACH PRESSURE GAUGE TO THE INLET PRESSURE TEST POINT

Next: p2518, !f2519

INSPECTION FLUE

Next: p2506, !f2507

INSPECTION GAS SUPPLY TUBE

Next: p2508, !f2509

INSPECTION FAN MEMBRANE

REMOVE AIR/GAS FAN ASSEMBLY

Next: p2510, ?2512, ?2514

INSPECTION BURNER

REMOVE FAN
REMOVE THE BURNER

Next: !p2516, !f2517

COMBUSTION SETTINGS HIGH AND LOW

Next: p2520, ?2522, ?2524

SPARKING PRESENT TEST

{GAINPCBACS}
REMO

Next: p2530, !f2531

CONDENSATE

Next: p2532, !f2533

INSPECTION FLUE OH STAT

Next: p2534, !f2535

INSPECTION GAS SUPPLY TUBE

Next: p2536, !f2537

ELECTRODE SENSE HARNESS

DISCONNECT FLAME SENSE LEAD FROM ELECTRODE
DISCONNECT CONNECTOR ST9 FROM THE PCB

Next: p2538, !f2539

ELECTRODE SPARK HARNESS

REMOVE THE IGNITION HARNESS CONNECTION FROM THE ELECTRODES TOP OF THE BURNER AND FROM THE PCB

Next: p2540, !f2541

INSPECTION ELECTRODES

REMOVE THE ELECTRODE ASSEMBLY

Next: p2542, !f2543

INSPECTION FAN MEMBRANE

REMOVE AIR/GAS FAN ASSEMBLY

Next: !p2544, ?2546, ?2548

CONDENSATE

Next: p2551, !f2552

INSPECTION GAS SUPPLY TUBE

Next: p2553, !f2554

INSPECTION SEAL INTEGRITY

Next: p2555, !f2556

INSPECTION FLUE

Next: !p2557, !f2558

CONDENSATE

Next: p2560, !f2561

INSPECTION GAS SUPPLY TUBE

Next: p2562, !f2563

INSPECTION SEAL INTEGRITY

Next: p2564, !f2565

INSPECTION FLUE

Next: !p2566, !f2567

RESISTANCE APS

DISCONNECT ONE OF THE ORANGE LEADS FROM THE AIR PRESSURE SWITCH

Next: p2575, !f2576

RESISTANCE OH STAT

DISCONNECT ONE OF THE ORANGE LEADS FROM THE OVERHEAT STAT

Next: p2577, !f2578

RESISTANCE FLUE OVERHEAT STAT

DISCONNECT ONE OF THE ORANGE LEADS FROM THE FLUE OVERHEAT STAT

Next: !p2579, !f2580

INSPECTION FLUE

Next: p1872, !f2594

INSPECTION FAN MEMBRANE

REMOVE AIR/GAS FAN ASSEMBLY

Next: p1873, ?2601, ?2603

RESISTANCE OH STAT

DISCONNECT ONE OF THE ORANGE LEADS FROM THE OVERHEAT STAT

Next: !p2611, !f2612

INSPECTION FLUE

Next: p1594, !f2726

INSPECTION BURNER

REMOVE FAN
REMOVE THE BURNER

Next: !p2734, !f2735

RESISTANCE PUMP AND HARNESS

{GAINPCBACS}

Next: p2737, f2738

RESISTANCE FAN AND HARNESS

DISCONNECT FAN CONNECTOR ST5 FROM THE PCB

Next: p2821, f2742

RESISTANCE PUMP AND HARNESS

{GAINPCBACS}

Next: p2761, f2762

RESISTANCE FAN AND HARNESS

DISCONNECT FAN CONNECTOR ST5 FROM THE PCB

Next: p2814, f2766

OBSERVATION REPLACE FUSE WITH FAN DISCONNECTED

REPLACE THE BLOWN FU

Next: !p2815, !f2862

OBSERVATION REPLACE FUSE WITH FAN DISCONNECTED

REPLACE THE BLOWN FU

Next: !p2822, !f2866

VOLTAGE FAN (AT PCB) - NEW STYLE

ENSURE NO DEMANDS

Next: p2829, ?2830, ?2832

KEYED PLUG

LOWER THE FACIA PANEL

Next: p2838, !f2839

VOLTAGE MAINS GND PWM AND HALL

REMOVE THE CONNECTOR FROM THE FAN AND MAKE SAFE
ENSURE NO DEMANDS

Next: p2834, !f2835

RESISTANCE FAN HARNESS

DISCONNECT THE FAN CONNECTOR FROM THE PCB
DISCONNECT THE FAN CONNECTOR FROM THE FAN ASSEMBLY

Next: !p2836, !f2837

RESISTANCE SENSOR TEMP FLOW AND HARNESS

DISCONNECT CONNECTOR FROM ST9 ON THE PCB

Next: p2840, f2841

VOLTAGE DEMAND TO FAN FROM PCB

REMOVE THE FAN CONNE

Next: p2844, !f2845

RESISTANCE FAN HARNESS

DISCONNECT THE FAN CONNECTOR FROM THE PCB
DISCONNECT THE FAN CONNECTOR FROM THE FAN ASSEMBLY

Next: !p2846, !f2847

FAN VOLTAGE CONTROL (PCB) - NEW STYLE

{GAINPCBACS}

Next: p2850, ?2851, ?2853

RESISTANCE FAN HARNESS

DISCONNECT THE FAN CONNECTOR FROM THE PCB
DISCONNECT THE FAN CONNECTOR FROM THE FAN ASSEMBLY

Next: !p2859, !f2860

RESISTANCE FAN HARNESS

DISCONNECT THE FAN CONNECTOR FROM THE PCB
DISCONNECT THE FAN CONNECTOR FROM THE FAN ASSEMBLY

Next: !p2857, !f2858

RESISTANCE FAN HARNESS

DISCONNECT THE FAN CONNECTOR FROM THE PCB
DISCONNECT THE FAN CONNECTOR FROM THE FAN ASSEMBLY

Next: !p2855, !f2856

FAN VOLTAGE CONTROL (PCB) - NEW STYLE

{GAINPCBACS}

Next: p2871, ?2872, ?2874

RESISTANCE FAN HARNESS

DISCONNECT THE FAN CONNECTOR FROM THE PCB
DISCONNECT THE FAN CONNECTOR FROM THE FAN ASSEMBLY

Next: !p2880, !f2881

RESISTANCE FAN HARNESS

DISCONNECT THE FAN CONNECTOR FROM THE PCB
DISCONNECT THE FAN CONNECTOR FROM THE FAN ASSEMBLY

Next: !p2878, !f2879

RESISTANCE FAN HARNESS

DISCONNECT THE FAN CONNECTOR FROM THE PCB
DISCONNECT THE FAN CONNECTOR FROM THE FAN ASSEMBLY

Next: !p2876, !f2877

VOLTAGE FAN (AT PCB) - NEW STYLE

ENSURE NO DEMANDS

Next: p2883, ?2884, ?2886

VOLTAGE DEMAND TO FAN FROM PCB

REMOVE THE FAN CONNE

Next: p2892, !f2893

VOLTAGE MAINS GND PWM AND HALL

REMOVE THE CONNECTOR FROM THE FAN AND MAKE SAFE
ENSURE NO DEMANDS

Next: p2888, !f2889

RESISTANCE FAN HARNESS

DISCONNECT THE FAN CONNECTOR FROM THE PCB
DISCONNECT THE FAN CONNECTOR FROM THE FAN ASSEMBLY

Next: !p2890, !f2891

RESISTANCE FAN HARNESS

DISCONNECT THE FAN CONNECTOR FROM THE PCB
DISCONNECT THE FAN CONNECTOR FROM THE FAN ASSEMBLY

Next: !p2894, !f2895

REMOVE FAN CONNECTOR IS BLUE LIGHT STILL OFF

REMOVE FAN CONNECTOR FROM PCB

Next: !p2897, f2898

PUMP LIMPET TEST

Next: p322, !f323

BYPASS SYSTEM

Next: p324, !f325

RESISTANCE SENSOR TEMP FLOW

DISCONNECT PLUG (RE

Next: p751, !f327

BYPASS SYSTEM

Next: !p1089, !f335

FAN RUNS

Next: p489, f569

RESISTANCE FUSE F1

REMOVE FUSE FROM FUSE AND HOLDER FROM PCB

Next: p2896, f572

CONDENSATE

Next: !p2702, !f766

CONDENSATE

Next: p840, !f844

GAS INLET PRESSURE

ATTACH PRESSURE GAUGE TO THE INLET PRESSURE TEST POINT

Next: p1591, !f845

GAS INLET PRESSURE

ATTACH PRESSURE GAUGE TO THE INLET PRESSURE TEST POINT

Next: p2036, !f890

System Information

  • Total Tests: 469
  • Sequence Logic: Decoded from encrypted .seq file
  • Navigation: Dynamic based on pass/fail results
  • Source: 4731307 GW SWIFTFLOW 100 SIT Control