Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect connector X11 from the PCB
Measurement:
Test 1:
Measure resistance between the spark generator neutral (marked 10.2 on X11) and live (marked 10.1 on X10).
Expect greater than 1M Ohm.
Disconnect connector X10 from the PCB.
Test 2:
Measure the resistance between the spark generator live (marked 10.1 on X10) and a suitable earth point.
Expect greater than 1M Ohm.
Test 3:
Measure the resistance between the spark generator neutral (marked 10.2 on X11) and a suitable earth point.
Expect greater than 1M Ohm.
Measure resistance between the spark generator neutral (marked 10.2 on X11) and live (marked 10.1 on X10).
Expect greater than 1M Ohm.
Disconnect connector X10 from the PCB.
Test 2:
Measure the resistance between the spark generator live (marked 10.1 on X10) and a suitable earth point.
Expect greater than 1M Ohm.
Test 3:
Measure the resistance between the spark generator neutral (marked 10.2 on X11) and a suitable earth point.
Expect greater than 1M Ohm.

Isolate as per TOPs P4
and refit as necessary