Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect the plug from the gas valve
Measurement:
Test 1:
Measure the resistance between Red (marked 7.1 on X11) at the PCB connector and pin 5 at the gas valve plug.
Test 2:
Measure the resistance between Blue (marked 7.2 on X11) at the PCB connector and pin 2 at the gas valve plug.
Test 3:
Measure the resistance between Orange (marked 7.3 on X11) at the PCB connector and pin 1 at the gas valve plug.
Expect continuity (zero resistance) on each test.
Measure the resistance between Red (marked 7.1 on X11) at the PCB connector and pin 5 at the gas valve plug.
Test 2:
Measure the resistance between Blue (marked 7.2 on X11) at the PCB connector and pin 2 at the gas valve plug.
Test 3:
Measure the resistance between Orange (marked 7.3 on X11) at the PCB connector and pin 1 at the gas valve plug.
Expect continuity (zero resistance) on each test.

Isolate as per TOPs P4
and refit as necessary