Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Gain access to PCB (use Insulation Mat as required)
Disconnect connector HV1 from the PCB
Disconnect connector HV1 from the PCB
Measurement:
Test 1:
Measure the resistance across the brown and blue wires on HV1.
Expect greater than 1M Ohm.
Test 2:
Measure the resistance between the brown wire on HV1 and a suitable earth point.
Expect greater than 1M Ohm.
Test 3:
Measure the resistance between the blue wire on HV1 and a suitable earth point.
Expect greater than 1M Ohm.
Measure the resistance across the brown and blue wires on HV1.
Expect greater than 1M Ohm.
Test 2:
Measure the resistance between the brown wire on HV1 and a suitable earth point.
Expect greater than 1M Ohm.
Test 3:
Measure the resistance between the blue wire on HV1 and a suitable earth point.
Expect greater than 1M Ohm.

Isolate as per TOPs P4
and refit as necessary