Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect the ignition leads from the spark generator
and position approx 2mm from the spark generator
with the use of a crocodile clip as shown in the picture
and position approx 2mm from the spark generator
with the use of a crocodile clip as shown in the picture
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
Reset appliance as necessary and allow the boiler to complete its self check.
Activate Test t1 in the display menu
(for information on how to access the test menu click here).
Sparking should then be observed for approximately 2 minutes between the spark generator and the lead.
Activate Test t1 in the display menu
(for information on how to access the test menu click here).
Sparking should then be observed for approximately 2 minutes between the spark generator and the lead.
Isolate as per TOPs P4
and refit as necessary