XSol Diagnostic System

Home

FAULT CODES



wc 27ri compact fault codes.jpg wc 30ri compact erp flash once per second.gif wc 30ri compact erp flash 4 in 2 seconds.gif wc-27i-ri-compact-fault-7-interpretation-example.gif
This symbol signifies a slow flash of once per second.
This symbol signifies 4 fast flashes within 2 seconds.
Interpretation Example:
Fault code 7 would display as a 5 second off period then 4 fast flashes followed by 2 slow flashes on a loop.
Observe the LED on the appliance, refer to the images below and the intermpretation example to establish the fault code, then select as appropriate from the options on the right hand side.
1: No Ionisation Detected After Ignition
 
2: Loss of Ionisation Signal During Operation
 
3: Gas Valve Error
 
4: First Safety Timing / Ignition Timing Error
 
5: False Flame / Flame Sensor or Gas Valve
 
6: Sensor Test Failed
 
7: Safety Temperature Too High
 
8: MAX Safety Thermostat Activated
 
9: Return Temperature Too High
 
10: Flow Temperature Too High
 
11: HCM (Code Plug) Defective
 
12: Fan Fault
 
13: Power Interrupted After Locking Error
 
14: Internal PCB Fault
 
15: All Other Faults