Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Gain access to PCB (use Insulation Mat as required)
Disconnect pump connector (middle plug) from the PCB
Disconnect pump connector (middle plug) from the PCB
Measurement:
Test 1:
Measure the resistance across the wire marked L and the wire marked N on the disconnected connector.
Expected resistance greater than 80 Ohms for standard pumps and greater than 1MOhm for ErP pumps.
Test 2:
Measure the resistance between the wire marked L on the disconnected connector and a suitable earth point.
Expected resistance greater than 1MOhm.
Test 3:
Measure the resistance between the wire marked N on the disconnected connector and a suitable earth point.
Expected resistance greater than 1MOhm.
Measure the resistance across the wire marked L and the wire marked N on the disconnected connector.
Expected resistance greater than 80 Ohms for standard pumps and greater than 1MOhm for ErP pumps.
Test 2:
Measure the resistance between the wire marked L on the disconnected connector and a suitable earth point.
Expected resistance greater than 1MOhm.
Test 3:
Measure the resistance between the wire marked N on the disconnected connector and a suitable earth point.
Expected resistance greater than 1MOhm.

Isolate as per TOPs P4
and refit as necessary