Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect connector X11 from the PCB
Measurement:
Test 1:
Measure the resistance across the Orange (marked 7.3) and Blue (marked 7.2) on X11.
Expect resistance of approximately 900 Ohms.
Test 2:
Measure the resistance across the Red (marked 7.1) and Blue (marked 7.2) on X11.
Expect resistance of approximately 6.1k Ohms.
Test 3: Measure resistance between each wire -
Red (marked 7.1), Blue (marked 7.2) and Orange (marked 7.3) and a suitable earth point.
Expect resistance greater than 1M Ohm on each wire.
Note:
Identification numbers for the fan connections are located on the PCB.
Measure the resistance across the Orange (marked 7.3) and Blue (marked 7.2) on X11.
Expect resistance of approximately 900 Ohms.
Test 2:
Measure the resistance across the Red (marked 7.1) and Blue (marked 7.2) on X11.
Expect resistance of approximately 6.1k Ohms.
Test 3: Measure resistance between each wire -
Red (marked 7.1), Blue (marked 7.2) and Orange (marked 7.3) and a suitable earth point.
Expect resistance greater than 1M Ohm on each wire.
Note:
Identification numbers for the fan connections are located on the PCB.

Isolate as per TOPs P4
and refit as necessary