Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to AC Volts Set meter to measure AC Volts
Gain access to PCB (use Insulation Mat as required)
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Allow boiler to enter fan lockout.
Measure the voltage between the brown wire marked 13.4
and the blue wire marked 13.5 at X11 on the PCB.
Mains voltage should be present.