Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to Resistance Set meter to measure resistance
Disconnect connector X11 from the PCB

Measurement:

Test 1:
Measure the resistance across the Orange (marked 7.3) and Blue (marked 7.2) on X11.
Expect resistance of approximately 900 Ohms.
Test 2:
Measure the resistance across the Red (marked 7.1) and Blue (marked 7.2) on X11.
Expect resistance of approximately 6.1k Ohms.
Note:
Identification numbers for the fan connections are located on the PCB.