Set Appliance State:
Mains Power Off
On/Off Switch On
No Demands
No Demands
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure the DC Voltages as follows between the Fan connector and the Neutral (blue) at the incoming mains connector on the PCB.
The Voltages should conform approximately to the table below:
The Voltages should conform approximately to the table below:
| Wire | DC Volts | Pink | 0 |
| Yellow | 13 |
| Black | 5 or 0 |

Isolate as per TOPs P4
and refit as necessary