Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect the Fan connector from the Fan
Measurement:
Test 1:
Measure the resistance between terminals 1 and 5 the two outermost terminals.
Expect approximately 110 - 130 ohms
Test 2:
Measure the resistance between each of the terminals at the fan connector to Earth in turn.
Expected resistance greater than 1 MOhm.
Note.
A reading of O.L on test 2 is acceptable as this is greater than 1 MOhm.
Measure the resistance between terminals 1 and 5 the two outermost terminals.
Expect approximately 110 - 130 ohms
Test 2:
Measure the resistance between each of the terminals at the fan connector to Earth in turn.
Expected resistance greater than 1 MOhm.
Note.
A reading of O.L on test 2 is acceptable as this is greater than 1 MOhm.

Isolate as per TOPs P4
and refit as necessary