Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove fan connector from the PCB
Measurement:
Measure the resistance between pin 1 (red) and
pin 3 (blue) on the fan connector.
Expected resistance between 110 - 130 Ohms.
pin 3 (blue) on the fan connector.
Expected resistance between 110 - 130 Ohms.

Isolate as per TOPs P4