Set Appliance State:

Mains Power Off
Set Multimeter to DC Volts Set meter to measure DC Volts
On/Off Switch On
No Demands
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Measure the DC Voltages as follows between the Fan connector and the Neutral (blue) at the incoming mains connector to the PCB
The Voltages should conform approximately to the table below:
WireDC Volts
Pink110
Yellow 94
Black105

Note:
The multimeter will register negative voltages.