Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to Resistance Set meter to measure resistance
Disconnect plug marked CON14 at the PCB

Measurement:

Test 1:
Measure the resistance between the blue and brown
wires at the disconnected plug.
Resistance should be between 1k - 1.3kΩ.
Test 2:
Measure the resistance at black wire at the
disconnected plug to a suitable earth point.
Resistance should be greater than 1MΩ (or O.L).
Note:
Gas valve plug may look different (no blank pins).
It is in the same location and resistances do not change.