Adjust, Service, Repair or Replace as necessary
Isolate Water and Gas as appropriate
Location:
Resistance tests have revealed no reason for the fuse failure. Replace the fuse (correctly rated fuse only) - if it blows again then the PCB may need to be replaced. It is also possible that a boiler component fails during operation i.e. pump, gas valve etc.
| Isolate Mains Power to appliance as per TOPs P4 |
Location:
Upon completion of the fault diagnostics carry out final electrical safety tests and checks as per TOPs (C6).
Refer to ADAPT for further information.