Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
CH Demand
Gain access to PCB (use Insulation Mat as required)
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure the voltage between the brown wire marked "GV2" and either of the blue wires marked "N" at the rightmost plug on the PCB.
Mains voltage should be present.
Note:
Two types of gas valve lead may be fitted, if you only
have one blue wire at the plug then use that one.
Mains voltage should be present.
Note:
Two types of gas valve lead may be fitted, if you only
have one blue wire at the plug then use that one.

Isolate as per TOPs P4
and refit as necessary