Set Appliance State:
Isolate Mains Power to appliance as per TOPs P4
Disconnect and remove the user control (display unit)
Remove the front cover
Disconnect and remove the user control (display unit)
Remove the front cover
Measurement:
Measure the resistance across the L/H side of the
CH potentiometer and the soldered connection
(bottom right of the four connections located centrally).
Resistances will differ as temperature selector is turned.
Resistances should conform (approximately) with the settings below.
Minimum demand - 166 kOhms.
Medium demand - 217 kOhms.
Maximum demand - 262 kOhms.
CH potentiometer and the soldered connection
(bottom right of the four connections located centrally).
Resistances will differ as temperature selector is turned.
Resistances should conform (approximately) with the settings below.
Minimum demand - 166 kOhms.
Medium demand - 217 kOhms.
Maximum demand - 262 kOhms.

Isolate as per TOPs P4
and refit as necessary