Set Appliance State:
Isolate Mains Power to appliance as per TOPs P4
Remove thermistor connector from PCB
(appliance will enter a fault code)
Remove thermistor connector from PCB
(appliance will enter a fault code)
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure the DC voltages between each of the wires on the fan connector listed in the table below and a suitable earth.
The Voltages should conform approximately to the table below:
Note:
Multimeter will register negative voltages.
The Voltages should conform approximately to the table below:
| Wire | DC Volts | Pink | 110 |
| Yellow | 94 |
| Black | 105 |
Note:
Multimeter will register negative voltages.

Isolate as per TOPs P4