Set Appliance State:

Set Multimeter to DC Volts Set meter to measure DC Volts
Isolate Mains Power to appliance as per TOPs P4
Remove thermistor connector from PCB
(appliance will enter a fault code)
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Measure the DC voltages between each of the wires on the fan connector listed in the table below and a suitable earth.
The Voltages should conform approximately to the table below:
WireDC Volts
Pink110
Yellow 94
Black105

Note:
Multimeter will register negative voltages.