Set Appliance State:

On/Off Switch OFF
Set Multimeter to DC Volts Set meter to measure DC Volts
Isolate Mains Power to appliance as per TOPs P4
Gain access to PCB connections as necessary
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Appliance On/Off switch On.
Measure voltage across connection 2 (+ve probe to red lead) and connection 1 (-ve probe to black lead) on connector J11 on the control PCB.
Expected voltage approximately 9 volts DC.