Set Appliance State:

On/Off Switch OFF
Set Multimeter to AC Volts Set meter to measure AC Volts
DHW Demand - Ensure Store is not up to Temperature
Isolate Mains Power to appliance as per TOPs P4
Gain access to PCB connections as necessary
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Appliance On/Off switch On.
Timer controls calling.
Reset lockout as necessary.
Measure voltage across connections 1 (brown lead) and
connection 2 (blue lead) on connector J8 on the PCB.