Set Appliance State:
Gas Off
On/Off Switch OFF
DHW Demand - Ensure Store is not up to Temperature
Isolate Mains Power to appliance as per TOPs P4
Remove the electrode lead from the ignition lead and place so it rests on the square housing of the spade (rotate the other end of the lead around the electrode as necessary)
Remove the electrode lead from the ignition lead and place so it rests on the square housing of the spade (rotate the other end of the lead around the electrode as necessary)
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
WARNING!
Sparking should occur approximately 15 to 20 seconds
after the appliance On/Off switch is switched on.
Appliance On/Off switch On.
Reset lockout as necessary.
Allow fan to run and ignition sequence to commence.
Is there a strong spark present between the earth lead
and the spark generator terminal?
Sparking should occur approximately 15 to 20 seconds
after the appliance On/Off switch is switched on.
Appliance On/Off switch On.
Reset lockout as necessary.
Allow fan to run and ignition sequence to commence.
Is there a strong spark present between the earth lead
and the spark generator terminal?
Isolate as per TOPs P4
and refit as necessary