Set Appliance State:

Set Multimeter to AC Volts Set meter to measure AC Volts
Isolate Mains Power to appliance as per TOPs P4
Remove the connector from the fan and make safe
NO demand
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Ensure both DHW and CH at the internal timer are turned OFF before continuing.
Measure the AC voltage between each of the 5 wires to the fan at the PCB and a suitable earth point
Voltages should be approximately as below:
WireVoltage (AC)
Yellow130
Black130
Red130
White130
Blue20