Set Appliance State:
Mains Power Off
Boiler Thermal Store must NOT be at maximum temperature.
Models with Programmer: Rocker Switch to Continuous.
Models without Programmer: Rocker Switch to On.
Models with Programmer: Rocker Switch to Continuous.
Models without Programmer: Rocker Switch to On.
| WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure |
Measurement:
Check for a Voltage of approximately 310 volts across
Connection 4 (on the 5 way Terminal Block) and
Neutral (Connection 1 on the 5 way Terminal Block).
Connection 4 (on the 5 way Terminal Block) and
Neutral (Connection 1 on the 5 way Terminal Block).

Isolate as per TOPs P4
and refit as necessary