Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect lead marked "HT" from the PCB
Remove burner assembly
Remove injector assembly
Remove burner assembly
Remove injector assembly
Measurement:
Check electrode is in good overall condition:
Ceramic uncracked
Electrode not warped or distorted
Gap between electrode and pilot assembly should be 3-5mm
Check for continuity (zero resistance)
between the tip of the electrode to the end of the lead.
Inspect the harness insulation is in good condition throughout
and there are no signs of shorting against the boiler chassis.
Note:
Ensure gasket is in good condition
and fitted correctly on reassembly.
Check for continuity (zero resistance)
between the tip of the electrode to the end of the lead.
Inspect the harness insulation is in good condition throughout
and there are no signs of shorting against the boiler chassis.
Note:
Ensure gasket is in good condition
and fitted correctly on reassembly.

Isolate as per TOPs P4
and refit as necessary