Set Appliance State:

Gas Off
Isolate Mains Power to appliance as per TOPs P4
CH Demand
Attach a pressure gauge to the inlet pressure test point
Gas On
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Observation:

Allow the burner to ignite and the appliance to run with a CH demand.
Is the inlet pressure satisfactory?
Note:
1. When pressure gauge is removed the pressure test point should be tightened and checked for gas tightness.
2. Refer to TOPs for more information on acceptable inlet pressures.