Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
CH Demand
Attach a pressure gauge to the burner pressure test point
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
Measure the burner pressure as the appliance operates.
The burner pressure should be correctly set as per the appliance data badge.
Is the burner pressure satisfactory?
Notes:
1. For range rated appliances confirm the burner pressure is correctly set for the systems requirements.
2. When pressure gauge is removed the pressure test point should be tightened and checked for gas tightness.
The burner pressure should be correctly set as per the appliance data badge.
Is the burner pressure satisfactory?
Notes:
1. For range rated appliances confirm the burner pressure is correctly set for the systems requirements.
2. When pressure gauge is removed the pressure test point should be tightened and checked for gas tightness.