Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove pump cover / plug
Measurement:
Test 1:
Measure the resistance between pump live and neutral connections.
Resistance should be greater than 120Ω.
Resistance on ErP pumps will be significantly higher.
Test 2:
Measure the resistance between pump live and earth connections.
Resistance should be greater than 1MΩ (or O.L).
Note:
For other designs of pump please refer to instruction
manual for which connection is live / neutral / earth.
Measure the resistance between pump live and neutral connections.
Resistance should be greater than 120Ω.
Resistance on ErP pumps will be significantly higher.
Test 2:
Measure the resistance between pump live and earth connections.
Resistance should be greater than 1MΩ (or O.L).
Note:
For other designs of pump please refer to instruction
manual for which connection is live / neutral / earth.

Isolate as per TOPs P4
and refit as necessary