Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove fuse from inline fuse holder
(push in and twist anticlockwise to undo)
(push in and twist anticlockwise to undo)
Measurement:
Measure the resistance across the fuse.
Expect continuity / zero resistance.
Is the resistance measured as expected?
Note:
If the resistance is as expected ensure the fuse is refitted after test.
Expect continuity / zero resistance.
Is the resistance measured as expected?
Note:
If the resistance is as expected ensure the fuse is refitted after test.

Isolate as per TOPs P4
and refit as necessary