A common issue with the Honeywell Ignition Control Box fitted to this appliance is that sometimes it will not reset from ignition lockout.
This issue can be overcome by carrying out the following procedure.
Step 1:
Step 2:
Remove the wire from pin 1 on the control box connector and make safe.
Step 3:
Mains Power On
Step 4:
Reset the ignition lockout
Step 5:
Refit the wire to pin 1 and operate the appliance as normal.
Note:
It may take several attempts to reset the lockout and it may be necessary to turn the mains power off and on in between attempts to reset while the wire at pin 1 is still disconnected. If the ignition control box will still not reset then it will need to be replaced click here for the part number.
This issue can be overcome by carrying out the following procedure.
Step 1:
| Isolate Mains Power to appliance as per TOP's P4 |
Step 2:
Remove the wire from pin 1 on the control box connector and make safe.
Step 3:
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Step 4:
Reset the ignition lockout
Step 5:
| Isolate Mains Power to appliance as per TOP's P4 |
Refit the wire to pin 1 and operate the appliance as normal.
Note:
It may take several attempts to reset the lockout and it may be necessary to turn the mains power off and on in between attempts to reset while the wire at pin 1 is still disconnected. If the ignition control box will still not reset then it will need to be replaced click here for the part number.