Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect the orange lead from the condensate drain cap
(This should already be disconnected from a previous test)
Remove the 10 way connector from the ignition PCB
(This should already be disconnected from a previous test)
Remove the 10 way connector from the ignition PCB
Measurement:
Test 1.
Measure the resistance between the disconnected orange
lead and pin 2 (orange wire) on the 10 way connector.
Expected resistance short circuit / zero resistance.
Test 2.
Measure the resistance between the disconnected orange
lead and a suitable earth point.
Expected resistance greater than 1 Mohm.
Also visually inspect the condition of the lead.
Measure the resistance between the disconnected orange
lead and pin 2 (orange wire) on the 10 way connector.
Expected resistance short circuit / zero resistance.
Test 2.
Measure the resistance between the disconnected orange
lead and a suitable earth point.
Expected resistance greater than 1 Mohm.
Also visually inspect the condition of the lead.

Isolate as per TOPs P4
and refit as necessary