Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Measurement:
Disconnect the Yellow spaded wire (connection 3) and the White spaded wire (connection 6) from the Control Thermostat and measure the Resistance between connections 3 and 6 on the Thermostat.
With the Control Thermostat in the Off position, Resistance open circuit.
With the Control Thermostat in its high position, Resistance short circuit.
With the Control Thermostat in the Off position, Resistance open circuit.
With the Control Thermostat in its high position, Resistance short circuit.

Isolate as per TOPs P4
and refit as necessary