Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect connector X14 from the PCB
Measurement:
Test 1:
Measure the resistance between the brown and blue wires on X14 connector.
Resistance should be approximately 160 Ohms or greater.
(ErP pumps will be significantly higher)
Test 2:
Measure the resistance between the brown wire on X14 connector
to a suitable earth point.
Resistance should be greater than 1M Ohm.
Test 3:
Measure the resistance between the blue wire on X14 connector
to a suitable earth point.
Resistance should be greater than 1M Ohm.
Measure the resistance between the brown and blue wires on X14 connector.
Resistance should be approximately 160 Ohms or greater.
(ErP pumps will be significantly higher)
Test 2:
Measure the resistance between the brown wire on X14 connector
to a suitable earth point.
Resistance should be greater than 1M Ohm.
Test 3:
Measure the resistance between the blue wire on X14 connector
to a suitable earth point.
Resistance should be greater than 1M Ohm.

Isolate as per TOPs P4
and refit as necessary