Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Gain access to pump wiring connections
Disconnect wires from the pump
Disconnect wires from the pump
Measurement:
Test 1:
Measure the resistance across the disconnected pump live and neutral.
Resistance should be approximately 160 Ohms or greater.
(ErP pumps will be significantly higher)
Test 2:
Measure the resistance between the disconnected pump live and earth.
Expect greater than 1M Ohm.
Test 3:
Measure the resistance between the disconnected pump neutral and earth.
Expect greater than 1M Ohm.
Note:
Pump located external to appliance and connections may differ.
Measure the resistance across the disconnected pump live and neutral.
Resistance should be approximately 160 Ohms or greater.
(ErP pumps will be significantly higher)
Test 2:
Measure the resistance between the disconnected pump live and earth.
Expect greater than 1M Ohm.
Test 3:
Measure the resistance between the disconnected pump neutral and earth.
Expect greater than 1M Ohm.
Note:
Pump located external to appliance and connections may differ.

Isolate as per TOPs P4
and refit as necessary