Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Gain access to PCB (use Insulation Mat as required)
Disconnect connector ST9 from the PCB and make safe
Disconnect connector ST9 from the PCB and make safe
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure for mains voltage across brown
and blue of ST4 pump connector on the PCB.
The connector is located at the back
of the PCB beneath the pump.
and blue of ST4 pump connector on the PCB.
The connector is located at the back
of the PCB beneath the pump.

Isolate as per TOPs P4
and refit as necessary