Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect fan connector at fan
Measurement:
Measure resistance across the fan terminals.
Note.
Black test probe connected to terminal 4 for all tests.
Expected resistances as below.
Note.
Black test probe connected to terminal 4 for all tests.
Expected resistances as below.
| Terminals | Resistance in Mega Ohms |
| 4 - 1 | Greater than 1 MOhms |
| 4 - 2 | Greater than 1 MOhms |
| 4 - 3 | Greater than 1 MOhms |
| 4 - 5 | Greater than 1 MOhms |

Isolate as per TOPs P4
and refit as necessary