Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove the two connectors from the gas valve
Observation:
Test 1.
Measure for resistance across the top two gas
valve solenoid terminals.
Expected resistance approximately 400 ohms.
Test 2.
Measure for resistance across the bottom two gas
valve solenoid terminals.
Expected resistance approximately 180 ohms.
Measure for resistance across the top two gas
valve solenoid terminals.
Expected resistance approximately 400 ohms.
Test 2.
Measure for resistance across the bottom two gas
valve solenoid terminals.
Expected resistance approximately 180 ohms.

Isolate as per TOPs P4
and refit as necessary