WORCESTER GREENSTAR I SYSTEM


CASE REMOVAL<

Next: &470, !f2

PUMP OVERRUN

CH TEMPERATURE CONTROL SET TO MAX

Next: &185, !f184

SYPHON OPERATION

Next: &nff, !f186

OBSERVATION BURNER IGNITION & ESTABLISH

ENSURE PRIMARY HEAT EXCHANGER IS COOL

Next: &1826, ?318, ?322, ?986, ?1509, ?2996

ENHANCED FAULT CODES


Next: &1052, !f467

TYPE OF DIAGNOSTIC PROCEDURE

PLEASE SELECT FROM O

Next: &2286, !f471

MAXIMUM OUTPUT MODE

INSTRUCTIONS TO S

Next: &nff, !f701

FURTHER INVESTIGATION OVERHEAT

NOT USED

Next: &nff, f911

POWER UP

Next: &2663, f1053

FURTHER INVESTIGATION FUSE BLOWN

NOT USED

Next: &nff, f2792

FAN PRESSURE TEST

ATTACH PRESSURE GAUGE TO FAN PRESSURE TEST POINT

Next: &1833, f2981

INLET PRESSURE

ATTACH PRESSURE GAUGE TO INLET PRESSURE TEST POINT ON GAS VALVE

Next: &1835, !f1834

COMBUSTION ANALYSIS MAX AND MIN

Next: &2702, ?1836, ?1838

OPERATIONAL SEQUENCE

NOT USED

Next: &466, !f2288

INTERNAL FAULT

NOT USED

Next: &nff, f2335

VOLATILE LOCK OUT

NOT USED

Next: &nff, f2339

BURNER SEAL CHECK FOR OVERHEAT

OUTSIDE MODEL

Next: &nff, f2501

OBSERVATION PUMP RUNS

Next: &317, f2664

OPERATION CH

CH TEMPERATURE CONTROL SET TO MAX

Next: &2741, ?2703, ?2705, ?2707, ?2709

OPERATION DHW

CH TEMPERATURE CONTROL SET TO MAX

Next: &183, ?2742, ?2744

INFORMATION FAN PCB REMOVAL

Next: &nff, !f3108

INFORMATION FAN DEMAND VOLTAGE

THE PWM OR (DEMAND/S

Next: &nff, !f3205

BURNER BAFFLES OUT

FLUE

Next: End

BLOWN STAND BY MODE AT POWER UP

FUSE (FUSED SPUR)

Next: End

LED AT POWER UP

PCB

Next: End

FAN DOES NOT RUN

Z DIRECTION

Next: End

BLOWN STANDBY MODE

FUSE - MAINS

Next: End

BLOWN STANDBY MODE

FUSE

Next: End

FURTHER IN VESTIGATION F2

Z DIRECTION

Next: End

BURNER IGNITION

TRANSFORMER

Next: End

OVERHEAT

DIRECTION CHOICE OR CONTINUE

Next: End

OVERHEAT

SENSOR - CONTROL

Next: End

PRIMARY TEST

INLET PRESSURE

Next: End

PUMP OVERRUN

PCB

Next: End

SYPHON

SIPHON ASSEMBLY

Next: End

OVERHEAT

LIMITER 120°C - TEMPERATURE

Next: End

ELECTRICAL SAFETY

ELECTRICAL SAFETY CHECKS

Next: End

BAFFLES OUT

TUBE GAS SUPPLY

Next: End

OPERATIONAL SEQUENCE

DIRECTION CHOICE OR CONTINUE

Next: End

INTERNAL FAULT

Z DIRECTION

Next: End

COMBUSTION INCORRECT

TUBE GAS SUPPLY

Next: End

DROPS OUT MIN MODE

TUBE GAS SUPPLY

Next: End

BURNER SEAL FOR OVERHEAT

FLUE / BURNER SEALS

Next: End

BURNER DOES NOT ESTABLISH

SIPHON ASSEMBLY

Next: End

FAN DOES NOT RUNFAULT CODE

CODE PLUG

Next: End

FAN DOES NOT RUN 1FAULT CODE

SENSOR - CONTROL

Next: End

FAN DOES NOT RUN

CODE PLUG

Next: End

OBSERVATION PUMP RUNS

CABLE - PUMP

Next: End

FAN DOES NOT RUN

SENSOR - CONTROL

Next: End

DHW COOL

SYSTEM PRESSURE

Next: End

BOILER AND RADS ONLY GET WARM

SENSOR - CONTROL

Next: End

EXPANSION VESSEL

EXPANSION VESSEL

Next: End

RADS DO NOT HEAT

SYSTEM PRESSURE

Next: End

RADS DO NOT HEAT

ISOLATION VALVES

Next: End

RADS DO NOT HEAT

PUMP

Next: End

RADS COLD

VALVE - BYPASS

Next: End

CH NOISY

SYSTEM PRESSURE

Next: End

CH NOISY

PUMP

Next: End

CH NOISY

SENSOR - CONTROL

Next: End

OVERHEAT INVESTIGATION

SYSTEM RESTRICTION OR BLOCKAGE

Next: End

FURTHER INVESTIGATION

GAS VALVE

Next: End

FAN RUNS OVERHEAT 1

LIMITER 120°C - TEMPERATURE

Next: End

FLUE OVERHEAT

BURNER

Next: End

FLUE OVERHEAT

PRIMARY HEAT EXCHANGER

Next: End

DOES NOT ESTABLISH

TUBE GAS SUPPLY

Next: End

DOES NOT ESTABLISH

BURNER

Next: End

FLAME SENSE BURNER IGNITES

HARNESS - MAINS

Next: End

BURNER IGNITES

ELECTRODE

Next: End

DOES NOT ESTABLISH 2

BURNER

Next: End

BURNER BAFFLES OUT 1

FLUE

Next: End

BAFFLES OUT 2

TUBE GAS SUPPLY

Next: End

BURNER BAFFLES OUT

BURNER

Next: End

FAN RUNS

LIMITER 120°C - TEMPERATURE

Next: End

BURNER IGNITION

LIMITER - TEMPERATURE

Next: End

BURNER IGNITES

SIPHON ASSEMBLY

Next: End

BURNER IGNITES

INLET PRESSURE

Next: End

BURNER DOES NOT IGNITE NO DROPFAN RUNS OVERHEAT 1

LIMITER 120°C - TEMPERATURE

Next: End

BURNER DOES NOT IGNITE NO DROP

LIMITER - TEMPERATURE

Next: End

NO VOLTAGE 1

PCB AND GAS VALVE

Next: End

BURNER DOES NOT IGNITE

PCB-HARNESS (MAIN)

Next: End

BURNER DOES NOT IGNITE

FLUE

Next: End

DOES NOT IGNITE 2

TUBE GAS SUPPLY

Next: End

BURNER DOES NOT IGNITE

BURNER

Next: End

DOES NOT IGNITE

TUBE GAS SUPPLY

Next: End

BURNER IGNITES

LEAD - IGNITION

Next: End

BURNER DOES NOT IGNITE

TUBE GAS SUPPLY

Next: End

BURNER IGNITES

ELECTRODE

Next: End

DOES NOT IGNITE

PRIMARY HEAT EXCHANGER

Next: End

FAN PRESSURE TEST

SIPHON ASSEMBLY

Next: End

FAN PRESSURE PRIMARY TEST

FLUE

Next: End

FAN PRESSURE TEST

TUBE GAS SUPPLY

Next: End

DHW BURNER IGNITION ESTABLISH - INTERMITTENT- HIGH RESIST

LIMITER - TEMPERATURE (CORROSION)

Next: End

FAN DOES NOT RUN - NEW STYLE

CABLE FAN CONNECTOR ASSEMBLY

Next: End

FAN RUNS - NEW STYLE

CABLE FAN CONNECTOR ASSEMBLY

Next: End

FAN RUNS

CABLE FAN CONNECTOR ASSEMBLY

Next: End

DOES NOT RUN

FAN

Next: End

FAN VOLTAGE PCB

PCB

Next: End

FAN DOES NOT RUN

CABLE FAN CONNECTOR ASSEMBLY

Next: End

FAN RUNS

FAN

Next: End

BETWEEN 125 VAC AND 135 VAC - NEW STYLE

CABLE FAN CONNECTOR ASSEMBLY

Next: End

ABOVE 135 VAC - NEW STYLE

CABLE FAN CONNECTOR ASSEMBLY

Next: End

STSLOW THEN TO TO HIGH SPEED - NEW STYLE

CABLE FAN CONNECTOR ASSEMBLY

Next: End

BETWEEN 125 VAC AND 135 VAC

CABLE FAN CONNECTOR ASSEMBLY

Next: End

ABOVE 135 VAC

CABLE FAN CONNECTOR ASSEMBLY

Next: End

SLOW THEN TO HIGH SPEED

FAN

Next: End

STSLOW THEN TO TO HIGH SPEED

CABLE FAN CONNECTOR ASSEMBLY

Next: End

BELOW 124 VAC

FAN

Next: End

INFORMATION FAN PCB REMOVAL

Z DIRECTION

Next: End

VOLATILE LOCKOUT BETWEEN 125 VAC AND 135 VAC - NEW STYLE

CABLE FAN CONNECTOR ASSEMBLY

Next: End

VOLATILE LOCKOUT ABOVE 135 VAC - NEW STYLE

CABLE FAN CONNECTOR ASSEMBLY

Next: End

VOLATILE LOCKOUT STSLOW THEN TO TO HIGH SPEED - NEW STYLE

CABLE FAN CONNECTOR ASSEMBLY

Next: End

VOLATILE LOCKOUT BETWEEN 125 VAC AND 135 VAC

CABLE FAN CONNECTOR ASSEMBLY

Next: End

VOLATILE LOCKOUT ABOVE 135 VAC

CABLE FAN CONNECTOR ASSEMBLY

Next: End

VOLATILE LOCKOUT STSLOW THEN TO TO HIGH SPEED

CABLE FAN CONNECTOR ASSEMBLY

Next: End

VOLATILE LOCKOUT FAN RUNS 1 - NEW STYLE

CABLE FAN CONNECTOR ASSEMBLY

Next: End

VOLATILE LOCKOUT FAN RUNS - NEW STYLE

CABLE FAN CONNECTOR ASSEMBLY

Next: End

FAN RUNS1 FAULT CODE

CABLE FAN CONNECTOR ASSEMBLY

Next: End

FAN DOES NOT RUN1 FAULT CODE

CABLE FAN CONNECTOR ASSEMBLY

Next: End

FAN RUNS1 FAULT CODE

FAN

Next: End

DOES NOT RUN1 FAULT CODE

FAN

Next: End

DOES NOT ESTABLISH

INLET PRESSURE

Next: End

FAULT CODES

ENHANCED FAULT CODES

Next: End

FOR TYPE DIAG PROCEDURE

DIRECTION CHOICE OR CONTINUE

Next: End

MAXIMUM OUTPUT INSTRUCTIONS

MAXIMUM OUTPUT INSTRUCTIONS

Next: End

OVERHEAT

SYSTEM PRESSURE

Next: End

OVERHEAT

PUMP

Next: End

BURNER BAFFLES OUT

SIPHON ASSEMBLY

Next: End

BURNER BAFFLES OUT

INLET PRESSURE

Next: End

BURNER BAFFLES OUT

GAS VALVE

Next: End

FURTHER INVESTIGATION FUSED SPUR

Z DIRECTION

Next: End

FURTHER INVESTIGATION F1

Z DIRECTION

Next: End

FURTHER INVESTIGATION F3

Z DIRECTION

Next: End

TRANSFORMER

PCB

Next: End

OVERHEAT

PCB

Next: End

OVERHEAT 2

LIMITER - TEMPERATURE

Next: End

INTERNAL FAULT

DIRECTION CHOICE OR CONTINUE

Next: End

CO2 SETTINGS INCORRECT

GAS VALVE SETTING RETEST

Next: End

DROPS OUT ON MINIMUM

GAS VALVE SETTING

Next: End

OVERHEAT OCCURED

NORMAL OPERATION

Next: End

FAN DOES NOT RUNFAULT CODE

HARNESS - MAINS

Next: End

OBSERVATION PUMP RUNS

PUMP

Next: End

FLOW SENSOR FAN RUNS 2

HARNESS - MAINS

Next: End

EXCESSIVE SYSTEM PRESSURE

HOSE - FLEXIBLE

Next: End

CH NOISY

PCB

Next: End

CH NOISY

HEAT EXCHANGER ASSEMBLY

Next: End

CH NOISY

Next: End

FURTHER INVESTIGATION FUSE F1 FURTHER INVESTIGATION

CABLE FAN CONNECTOR ASSEMBLY

Next: End

GAS VALVE OVERHEAT 1

PCB

Next: End

DOES NOT IGNITE2

LIMITER - TEMPERATURE (CORROSION)

Next: End

APS/FLUE/OH OVERHEAT 1

HARNESS - MAINS

Next: End

BURNER IGNITION OVERHEAT 1

LIMITER - TEMPERATURE

Next: End

BURNER DOES NOT IGNITE

MEMBRANE

Next: End

BURNER DOES NOT IGNITE

FAN

Next: End

BURNER DOES NOT EST

PRIMARY HEAT EXCHANGER

Next: End

FLAME SENSE

PCB

Next: End

SHORTING TO EARTH

ELECTRODE

Next: End

BURNER DOES NOT ESTABLISH

GAS VALVE

Next: End

BAFFLES OUT

MEMBRANE

Next: End

BAFFLES OUT

FAN

Next: End

BURNER BAFFLES OUT

PRIMARY HEAT EXCHANGER

Next: End

DOES NOT IGNITE - OPEN CIRCUIT

LIMITER - TEMPERATURE (CORROSION)

Next: End

APS/FLUE/OH

HARNESS - MAINS

Next: End

DOES NOT IGNITE - HIGH RESIST

LIMITER - TEMPERATURE (CORROSION)

Next: End

BURNER DOES NOT IGNITE NO DROP OVERHEAT

HARNESS - MAINS

Next: End

VOLTAGE GAS VALVE 1

PCB

Next: End

BURNER DOES NOT IGNITE

HARNESS - MAINS

Next: End

NOT IGNITING NO DROP

MEMBRANE

Next: End

NOT IGNITING NO DROP

FAN

Next: End

BURNER DOES NOT IGNITE2

PRIMARY HEAT EXCHANGER

Next: End

BURNER DOES NOT IGNITE 2

GAS VALVE

Next: End

NOT IGNITING WITH DROP

MEMBRANE

Next: End

NOT IGNITING WITH DROP

FAN

Next: End

BURNER DOES NOT IGNITE

GAS VALVE

Next: End

FAN PRESSURE TEST

MEMBRANE

Next: End

FAN PRESSURE TEST

FAN

Next: End

PRIMARY PRE TEST FAN PRESSURE

PRIMARY HEAT EXCHANGER

Next: End

DHW BURNER IGNITION ESTABLISH - INTERMITTENT 2

PRIMARY HEAT EXCHANGER

Next: End

DHW BURNER IGNITION ESTABLISH - INTERMITTENT

GAS VALVE SETTING RETEST

Next: End

DHW BURNER IGNITION ESTABLISH - INTERMITTENT

GAS VALVE SETTING

Next: End

DHW BURNER IGNITION ESTABLISH - INTERMITTENT

NO FAULT INTERMITTENT IGNITION

Next: End

DOES NOT RUN - NEW STYLE

FAN

Next: End

FAN RUNS - NEW STYLE

FAN

Next: End

FAN DOES NOT RUN

PCB

Next: End

DOES NOT RUN

FAN PCB

Next: End

FAN RUNS

FAN PCB

Next: End

FAN REDUCES AND STOPS

PCB

Next: End

SLOW THEN TO HIGH SPEED

FAN PCB

Next: End

BELOW 124 VAC

FAN PCB

Next: End

FUSE INVESTIGATION

FAN PCB

Next: End

VOLATILE LOCKOUT BELOW 124 VAC

FAN PCB

Next: End

FAN RUNS1 FAULT CODE

FAN PCB

Next: End

DOES NOT RUN1 FAULT CODE

FAN PCB

Next: End

FAN RUNS BUT BURNER DOES NOT IGNITE

CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION & ESTABLISH

Next: p2886

CO2 SETTINGS INCORRECT

CHARACTERISTIC TEST FROM COMBUSTION ANALYSIS MAX AND MIN

Next: p2433

BURNER DROPS OUT IN MINIMUM MODE

CHARACTERISTIC TEST FROM COMBUSTION ANALYSIS MAX AND MIN

Next: p2437

VOLATILE LOCKOUT DISPLAYED WITHIN 10 SECONDS, FAN DOES NOT RUN

CHARACTERISTIC TEST FROM OBSERVATION BLUE LED - FAULT CODE

Next: p2593

VOLATILE LOCKOUT DISPLAYED AFTER MORE THAN 20 SECONDS, FAN DOES NOT RUN

CHARACTERISTIC TEST FROM OBSERVATION BLUE LED - FAULT CODE

Next: p3145

BOILER NOISY

CHARACTERISTIC TEST FROM OPERATION CH

Next: p2704

BOILER REACHES TEMPERATURE, RADS DO NOT HEAT OR ONLY GET WARM

CHARACTERISTIC TEST FROM OPERATION CH

Next: p2706

EXCESSIVE SYSTEM PRESSURE RISE

CHARACTERISTIC TEST FROM OPERATION CH

Next: p2708

BOILER AND RADIATORS ONLY GET WARM

CHARACTERISTIC TEST FROM OPERATION CH

Next: p2710

TEMPERATURE DIFFERENTIAL INCORRECT LOCAL NOISE

CHARACTERISTIC TEST FROM DIFFERENTIAL FLOW RETURN

Next: !p2738

DIFFERENTIAL OK SYSTEM NOISE

CHARACTERISTIC TEST FROM DIFFERENTIAL FLOW RETURN

Next: !p2740

BOILER DOES NOT RESPOND TO DHW DEMAND

CHARACTERISTIC TEST FROM OPERATION DHW

Next: !p2743

DHW OPERATION UNSATISFACTORY

CHARACTERISTIC TEST FROM OPERATION DHW

Next: !p2745

FLUE STAT CORRODED, DAMAGED AND/OR MOISTURE PRESENT

CHARACTERISTIC TEST FROM RESISTANCE SAFETY CIRCUIT

Next: !p2831

RESISTANCE NOT AS EXPECTED

CHARACTERISTIC TEST FROM RESISTANCE SAFETY CIRCUIT

Next: p2833

FAN MEMBRANE DAMAGED OR WORN

CHARACTERISTIC TEST FROM INSPECTION FAN MEMBRANE

Next: !p2852

FAN STIFF TO TURN OR SEIZED

CHARACTERISTIC TEST FROM INSPECTION FAN MEMBRANE

Next: !p2854

VOLTAGE PRESENT ON TEST 1 BUT DOES NOT DROP OR FLUCTUATES

CHARACTERISTIC TEST FROM RECTIFICATION VOLTAGE

Next: p2860

VOLTAGE ABSENT ON TEST 1

CHARACTERISTIC TEST FROM RECTIFICATION VOLTAGE

Next: p2862

FAN MEMBRANE DAMAGED OR WORN

CHARACTERISTIC TEST FROM INSPECTION FAN MEMBRANE

Next: !p2881

FAN STIFF TO TURN OR SEIZED

CHARACTERISTIC TEST FROM INSPECTION FAN MEMBRANE

Next: !p2883

FLUE STAT CORRODED, DAMAGED, OR MOISTURE PRESENT

CHARACTERISTIC TEST FROM RESISTANCE SAFETY CIRCUIT

Next: !p2891

RESISTANCE NOT AS EXPECTED

CHARACTERISTIC TEST FROM RESISTANCE SAFETY CIRCUIT

Next: p2893

FLUE STAT CORRODED, DAMAGED, OR MOISTURE PRESENT

CHARACTERISTIC TEST FROM RESISTANCE SAFETY CIRCUIT

Next: !p2920

RESISTANCE NOT AS EXPECTED

CHARACTERISTIC TEST FROM RESISTANCE SAFETY CIRCUIT

Next: p2922

FAN MEMBRANE DAMAGED OR WORN

CHARACTERISTIC TEST FROM INSPECTION FAN MEMBRANE

Next: !p2946

FAN STIFF TO TURN OR SEIZED

CHARACTERISTIC TEST FROM INSPECTION FAN MEMBRANE

Next: !p2948

FAN MEMBRANE DAMAGED OR WORN

CHARACTERISTIC TEST FROM INSPECTION FAN MEMBRANE

Next: !p2960

FAN STIFF TO TURN OR SEIZED

CHARACTERISTIC TEST FROM INSPECTION FAN MEMBRANE

Next: !p2962

FAN MEMBRANE DAMAGED OR WORN

CHARACTERISTIC TEST FROM INSPECTION FAN MEMBRANE

Next: !p2991

FAN STIFF TO TURN OR SEIZED

CHARACTERISTIC TEST FROM INSPECTION FAN MEMBRANE

Next: !p2993

BURNER DOES NOT IGNITE SMOOTHLY / INTERMITTENT IGNITION

CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION & ESTABLISH

Next: p2997

FAN MEMBRANE DAMAGED OR WORN

CHARACTERISTIC TEST FROM INSPECTION FAN MEMBRANE

Next: !p3009

FAN STIFF TO TURN OR SEIZED

CHARACTERISTIC TEST FROM INSPECTION FAN MEMBRANE

Next: !p3011

BURNER DROPS OUT IN MINIMUM MODE

CHARACTERISTIC TEST FROM COMBUSTION ANALYSIS MAX AND MIN

Next: p3019

CO2 SETTINGS INCORRECT

CHARACTERISTIC TEST FROM COMBUSTION ANALYSIS MAX AND MIN

Next: p3021

FAN MEMBRANE DAMAGED OR WORN

CHARACTERISTIC TEST FROM INSPECTION FAN MEMBRANE

Next: !p3043

FAN STIFF TO TURN OR SEIZED

CHARACTERISTIC TEST FROM INSPECTION FAN MEMBRANE

Next: !p3045

240 VOLTS ABSENT BETWEEN PURPLE/BROWN

CHARACTERISTIC TEST FROM VOLTAGE FAN (AT PCB)

Next: !p3051

240 VOLTS PRESENT BETWEEN PURPLE/BROWN BUT OTHERS NOT AS ABOVE

CHARACTERISTIC TEST FROM VOLTAGE FAN (AT PCB)

Next: p3180

240 VOLTS ABSENT BETWEEN PURPLE/BROWN

CHARACTERISTIC TEST FROM VOLTAGE FAN (AT PCB)

Next: !p3063

240 VOLTS PRESENT BETWEEN PURPLE/BROWN BUT OTHERS NOT AS ABOVE

CHARACTERISTIC TEST FROM VOLTAGE FAN (AT PCB)

Next: p3184

VOLTAGE ABOVE 120 VAC

CHARACTERISTIC TEST FROM FAN VOLTAGE CONTROL (PCB) - NEW STYLE

Next: p3082

VOLTAGE BETWEEN 110 VAC AND 120 VAC

CHARACTERISTIC TEST FROM FAN VOLTAGE CONTROL (PCB) - NEW STYLE

Next: p3084

VOLTAGE ABOVE 135 VAC

CHARACTERISTIC TEST FROM FAN VOLTAGE CONTROL (PCB)

Next: p3094

VOLTAGE BETWEEN 124 VAC AND 135 VAC

CHARACTERISTIC TEST FROM FAN VOLTAGE CONTROL (PCB)

Next: p3096

VOLTAGE ABOVE 120 VAC

CHARACTERISTIC TEST FROM FAN VOLTAGE CONTROL (PCB) - NEW STYLE

Next: p3120

VOLTAGE BETWEEN 110 VAC AND 120 VAC

CHARACTERISTIC TEST FROM FAN VOLTAGE CONTROL (PCB) - NEW STYLE

Next: p3122

VOLTAGE ABOVE 135 VAC

CHARACTERISTIC TEST FROM FAN VOLTAGE CONTROL (PCB)

Next: p3132

VOLTAGE BETWEEN 124 VAC AND 135 VAC

CHARACTERISTIC TEST FROM FAN VOLTAGE CONTROL (PCB)

Next: p3134

240 VOLTS ABSENT BETWEEN PURPLE/BROWN

CHARACTERISTIC TEST FROM VOLTAGE FAN (AT PCB)

Next: !p3150

240 VOLTS PRESENT BETWEEN PURPLE/BROWN BUT OTHERS NOT AS ABOVE

CHARACTERISTIC TEST FROM VOLTAGE FAN (AT PCB)

Next: p3198

240 VOLTS ABSENT BETWEEN PURPLE/BROWN

CHARACTERISTIC TEST FROM VOLTAGE FAN (AT PCB)

Next: !p3162

240 VOLTS PRESENT BETWEEN PURPLE/BROWN BUT OTHERS NOT AS ABOVE

CHARACTERISTIC TEST FROM VOLTAGE FAN (AT PCB)

Next: p3192

BURNER IGNITES SMOOTHLY, BUT DOES NOT ESTABLISH

CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION & ESTABLISH

Next: p319

FAN DOES NOT RUN

CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION & ESTABLISH

Next: p1632

BURNER IGNITES BUT BAFFLES

CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION & ESTABLISH

Next: p987

VOLTAGE MAINS POWER INPUT TO APPLIANCE

{GAINPCBACS}

Next: p1054, f1055

RESISTANCE FUSE (FUSED SPUR)

REMOVE FUSE FROM FUSED SPUR

Next: !p1056, f1057

FUSE FURTHER INVESTIGATION

Next: !p1058, !f1059

FUSE F1

REMOVE CONTROL BOX COVER IF NECESSARY

Next: p1635, f1636

FUSE FURTHER INVESTIGATION F1

Next: !p1637, !f1638

FUSE FURTHER INVESTIGATION F3

Next: !p1641, !f1642

FUSE FURTHER INVESTIGATION F2

Next: !p1645, !f1646

RESISTANCE OH STAT

DISCONNECT ONE OF THE ORANGE LEADS FROM THE OVERHEAT STAT

Next: !p1990, !f1991

PUMP VOLTAGE

{GAINPCBACS}

Next: p2201, !f2202

INTERNAL FAULT RESET

Next: !p2336, !f2337

OBSERVATION BLUE LED - FAULT CODE

PREHEAT SWITCHED OFF (ECO BUTTON ILLUMINATED)

Next: p3115, ?2591, ?2604

INSPECTION SEAL INTEGRITY

Next: !p2505, !f2506

RESISTANCE SENSOR TEMP FLOW

DISCONNECT PLUG (RE

Next: !p2598, !f2599

OBSERVATION PUMP RUNS LOCKOUT

{GAINPCBACS}
DISCONNECT CONNECTOR ST9 FROM THE PCB AND MAKE SAFE

Next: p2807, f2666

VOLTAGE PUMP AT PCB (LOCKOUT)

{GAINPCBACS}
DISCONNECT CONNECTOR ST9 FROM THE PCB AND MAKE SAFE

Next: p2667, !f2668

RESISTANCE SENSOR TEMP FLOW

DISCONNECT PLUG (RE

Next: !p2688, !f2689

RESISTANCE SIT GAS VALVE AND HARNESS - FURTHER INVESTIGATION

REMOVE ST9 CONNECTOR

Next: p2793, f2794

RESISTANCE - SIT GAS VALVE SOLENOIDS

REMOVE THE TWO CONNECTORS FROM THE GAS VALVE

Next: !p2795, !f2796

RESISTANCE PUMP

DISCONNECT THE PUMP CONNECTOR
ENSURE PUMP SPEED SELECTOR IS SET TO POSITION 3

Next: !p2799, !f2800

RESISTANCE FAN

DISCONNECT FAN CONNECTOR AT FAN

Next: !p2803, f3109

EXTERNAL CONTROL VOLTAGE (SEND)

Next: !p2810, !f2811

RESISTANCE SAFETY CIRCUIT

DISCONNECT CONNECTOR

Next: !p2829, ?2830, ?2832

BURNER INSPECTION

REMOVE FAN/MANIFOLD ASSEMBLY
REMOVE THE BURNER/BAFFLES ASSEMBLY

Next: p2838, !f2839

INSPECTION FLUE

Next: p2847, !f2848

INSPECTION HARNESS ELECTRODE SENSE

DISCONNECT THE CONNECTOR FROM THE FLAME SENSE
ELECTRODE AT THE TOP OF THE APPLIANCE

Next: !p2865, !f2866

INSPECTION FLUE

Next: p2874, !f2875

RESISTANCE SAFETY CIRCUIT

DISCONNECT CONNECTOR

Next: p3077, ?2890, ?2892

RESISTANCE SAFETY CIRCUIT

DISCONNECT CONNECTOR

Next: p2918, ?2919, ?2921

RESISTANCE - SIT GAS VALVE SOLENOIDS

REMOVE THE TWO CONNECTORS FROM THE GAS VALVE

Next: p2929, !f2930

RESISTANCE - SIT GAS VALVE SOLENOIDS

REMOVE THE TWO CONNECTORS FROM THE GAS VALVE

Next: !p2935, !f2936

INSPECTION FLUE

Next: p2939, !f2940

CONDENSATE PIPE

Next: p2982, !f2983

CONDENSATE PIPE

Next: p3000, !f3001

VOLTAGE FAN (AT PCB) - NEW STYLE

MOVE CONNECTOR ST5 U

Next: p3049, ?3050, ?3052

FAN VOLTAGE CONTROL (PCB) - NEW STYLE

{GAINPCBACS}
MOVE CONNECTOR ST5 TO EXPOSE TERMINALS ON PCB

Next: p3080, ?3081, ?3083

OBSERVATION FAN TYPE

Next: p3110, !f3111

FAN VOLTAGE CONTROL (PCB) - NEW STYLE

{GAINPCBACS}
MOVE CONNECTOR ST5 TO EXPOSE TERMINALS ON PCB

Next: p3118, ?3119, ?3121

VOLTAGE FAN (AT PCB) - NEW STYLE

MOVE CONNECTOR ST5 U

Next: p3148, ?3149, ?3151

BOILER RESET - OVERHEAT

ENSURE BOILER HAS COOLED

Next: p923, f2828

FAN RUNS DHW DEMAND

Next: p1060, !f1139

FURTHER INVESTIGATION LED PROBLEM

Next: !p1072, !f1073

VOLTAGE AT PCB

{GAINPCBACS}

Next: p1633, f1634

INSPECTION CODE PLUG

LOWER THE FACIA PANEL

Next: p2685, !f2657

FUSE F3

REMOVE CONTROL BOX C

Next: p1639, f1640

FUSE F2

REMOVE CONTROL BOX C

Next: p1643, f1644

TRANSFORMER RESISTANCE

REMOVE THE BACK PLATE OF THE CONTROL BOX AND THE TRANSFORMER FROM THE PCB

Next: !p1647, !f1648

RUN BOILER TO MAX TEMP-DOES OVERHEAT OCCUR

ATTACH TEMPERATURE CLAMP TO FLOW PIPE
SET BOILER TEMPERATURE CONTROL TO MAX

Next: p1789, f1989

COOL APPLIANCE

ENSURE ALL RADS ARE TURNED ON
ATTACH TEMPERATURE CLAMP TO FLOW PIPE

Next: p1797, !f1798

PRIMARY SENSOR (HIGH FLAME)

DISCONNECT PLUG (RE

Next: !p1799, !f1800

INSPECTION GAS SUPPLY TUBE

Next: p992, !f2134

PUMP RUNNING

Next: p924, f2200

PUMP HARNESS CONTINUITY

REMOVE THE ELECTRICAL CONNECTOR FROM THE PUMP AND
THE PUMP CONNECTOR ST4 FROM THE PCB

Next: !p2203, !f2204

DIFFERENTIAL PRIMARY HEAT EXCHANGER

CH TEMPERATURE CONTR

Next: p1788, !f2777

INSPECTION GAS SUPPLY TUBE

Next: !p2434, !f2436

INSPECTION GAS SUPPLY TUBE

Next: !p2438, !f2439

CONDENSATE PIPE

Next: p2842, !f2560

INSPECTION CODE PLUG

LOWER THE FACIA PANEL

Next: p2594, !f2595

RESISTANCE SENSOR TEMP FLOW AND HARNESS

DISCONNECT CONNECTOR

Next: !p2779, f2597

PUMP HARNESS CONTINUITY

REMOVE THE ELECTRICAL CONNECTOR FROM THE PUMP AND
THE PUMP CONNECTOR ST4 FROM THE PCB

Next: !p2669, !f2670

RESISTANCE SENSOR TEMP FLOW AND HARNESS

DISCONNECT CONNECTOR

Next: p3046, f2687

INSPECTION VESSEL PRESSURE

CLOSE FLOW AND RETURN ISOLATION VALVES
DISCHARGE PRIMARY SYSTEM WATER

Next: !p2717, !f2718

PUMP LIMPET TEST

Next: p2713, !f2714

RESISTANCE SENSOR TEMP FLOW

DISCONNECT PLUG (RE

Next: !p2715, !f2716

PUMP LIMPET TEST

Next: p2723, !f2724

BYPASS (INTERNAL)

ENSURE RADS ARE OPEN AND WATER CAN CIRCULATE AROUND THE SYSTEM
USE AN FGA TEMPERATURE PROBE

Next: !p2725, !f2726

PUMP LIMPET TEST

Next: p2731, !f2732

PRIMARY SENSOR (HIGH FLAME)

DISCONNECT PLUG (RE

Next: p2733, !f2734

DIFFERENTIAL FLOW RETURN

TEMPERATURE CONTROL SET TO MAX
ATTACH TEMPERATURE CLAMPS TO FLOW AND RETURN PIPES

Next: !p2735, ?2737, ?2739

RESISTANCE PUMP AND HARNESS

REMOVE THE PUMP CONNECTOR ST4 FROM THE PCB
ENSURE PUMP SPEED SELECTOR IS SET TO POSITION 3

Next: p2797, f2798

RESISTANCE FAN AND HARNESS

DISCONNECT FAN CONNECTOR ST5 FROM THE PCB

Next: p2801, f2802

RESISTANCE TRANSFORMER

REMOVE THE BACK PLATE OF THE CONTROL BOX AND THE TRANSFORMER FROM THE PCB

Next: !p2805, !f2806

EXTERNAL CONTROLS VOLTAGE (RETURN)

{GAINPCBACS}
EXTERNAL CONTROLS CALLING FOR HEAT

Next: !p2808, f2809

RESISTANCE OH STAT

DISCONNECT ONE OF THE ORANGE LEADS FROM THE OVERHEAT STAT

Next: p2834, !f2835

RESISTANCE FLUE OH STAT

DISCONNECT ONE OF THE ORANGE LEADS FROM THE OVERHEAT STAT

Next: !p2836, f2837

INSPECTION HEAT EXCHANGER

REMOVE FAN/MANIFOLD

Next: !p2840, !f2841

INSPECTION GAS SUPPLY TUBE

Next: p2843, !f2844

FAN PRESSURE TEST (IGNITION)

ATTACH PRESSURE GAUGE TO FAN PRESSURE TEST POINT

Next: p2845, f2846

RECTIFICATION VOLTAGE

{GAINPCBACS}

Next: !p2857, ?2859, ?2861

INSPECTION FAN MEMBRANE

REMOVE FAN ASSEMBLY FROM APPLIANCE

Next: p2849, ?2851, ?2853

BURNER INSPECTION

REMOVE FAN/MANIFOLD ASSEMBLY
REMOVE THE BURNER/BAFFLES ASSEMBLY

Next: !p2855, !f2856

ELECTRODE SENSE HARNESS

DISCONNECT FLAME SEN

Next: p2867, !f2868

RESISTANCE HARNESS ELECTRODE SENSE TO EARTH

DISCONNECT CONNECTER

Next: !p2863, f2864

ELECTRODE SENSE

REMOVE THE ELECTRODE ASSEMBLY

Next: p2869, !f2870

BURNER INSPECTION

REMOVE FAN/MANIFOLD ASSEMBLY
REMOVE THE BURNER/BAFFLES ASSEMBLY

Next: !p2871, !f2872

INSPECTION GAS SUPPLY TUBE

Next: p2876, !f2877

INSPECTION FAN MEMBRANE

REMOVE FAN ASSEMBLY FROM APPLIANCE

Next: p2878, ?2880, ?2882

BURNER INSPECTION

REMOVE FAN/MANIFOLD ASSEMBLY
REMOVE THE BURNER/BAFFLES ASSEMBLY

Next: !p2884, !f2885

SPARKING PRESENT TEST

REMOVE SPARK LEADS F

Next: p2887, f2888

CONDENSATE PIPE

Next: p2912, !f2913

RESISTANCE OH STAT

DISCONNECT ONE OF THE ORANGE LEADS FROM THE OVERHEAT STAT

Next: p2894, !f2895

RESISTANCE FLUE OH STAT

DISCONNECT ONE OF THE ORANGE LEADS FROM THE OVERHEAT STAT

Next: !p2896, !f2897

INLET PRESSURE

ATTACH PRESSURE GAUGE TO INLET PRESSURE TEST POINT ON GAS VALVE

Next: p2914, !f2915

PRESSURE GAS INLET DROP

ATTACH PRESSURE GAUGE TO INLET PRESSURE TEST POINT ON GAS VALVE

Next: p2916, f2917

ELECTRODE SPARK HARNESS

REMOVE THE IGNITION HARNESS CONNECTION FROM THE
ELECTRODES TOP OF THE BURNER AND FROM THE PCB

Next: p2953, !f2954

VOLTAGE GAS VALVE AT PCB

{GAINPCBACS}
REMOVE THE GAS VALVE CONNECTORS FROM THE GAS VALVE AND MAKE SAFE

Next: p2927, f2928

RESISTANCE OH STAT

DISCONNECT ONE OF THE ORANGE LEADS FROM THE OVERHEAT STAT

Next: p2923, !f2924

RESISTANCE FLUE OH STAT

DISCONNECT ONE OF THE ORANGE LEADS FROM THE OVERHEAT STAT

Next: !p2925, !f2926

RESISTANCE - SIT GAS VALVE AND HARNESS

REMOVE ST9 CONNECTOR

Next: p2933, f2934

RESISTANCE GAS VALVE HARNESS

REMOVE THE CONNECTOR

Next: !p2931, !f2932

FAN PRESSURE TEST (IGNITION)

ATTACH PRESSURE GAUGE TO FAN PRESSURE TEST POINT

Next: p2937, f2938

INSPECTION GAS SUPPLY TUBE

Next: !p2951, !f2952

INSPECTION GAS SUPPLY TUBE

Next: p2941, !f2942

INSPECTION FAN MEMBRANE

REMOVE FAN ASSEMBLY FROM APPLIANCE

Next: p2943, ?2945, ?2947

BURNER INSPECTION

REMOVE FAN/MANIFOLD ASSEMBLY
REMOVE THE BURNER/BAFFLES ASSEMBLY

Next: !p2949, !f2950

INSPECTION GAS SUPPLY TUBE

Next: p2955, !f2956

INSPECTION FAN MEMBRANE

REMOVE FAN ASSEMBLY FROM APPLIANCE

Next: p2957, ?2959, ?2961

INSPECTION SPARK ELECTRODE

REMOVE THE ELECTRODE ASSEMBLY

Next: p2963, !f2964

BURNER INSPECTION

REMOVE FAN/MANIFOLD ASSEMBLY
REMOVE THE BURNER/BAFFLES ASSEMBLY

Next: p2965, !f2966

INSPECTION HEAT EXCHANGER

REMOVE FAN/MANIFOLD

Next: !p2967, !f2968

INSPECTION FLUE

Next: p2984, !f2985

INSPECTION GAS SUPPLY TUBE

Next: p2986, !f2987

INSPECTION FAN MEMBRANE

REMOVE FAN ASSEMBLY FROM APPLIANCE

Next: p2988, ?2990, ?2992

BURNER INSPECTION

REMOVE FAN/MANIFOLD ASSEMBLY
REMOVE THE BURNER/BAFFLES ASSEMBLY

Next: !p2994, !f2995

FAN PRESSURE TEST

ATTACH PRESSURE GAUGE TO FAN PRESSURE TEST POINT

Next: p2998, f2999

INLET PRESSURE

ATTACH PRESSURE GAUGE TO INLET PRESSURE TEST POINT ON GAS VALVE

Next: p3014, !f3015

INSPECTION FLUE

Next: p3002, !f3003

INSPECTION GAS SUPPLY TUBE

Next: p3004, !f3005

INSPECTION FAN MEMBRANE

REMOVE FAN ASSEMBLY FROM APPLIANCE

Next: p3006, ?3008, ?3010

BURNER INSPECTION

REMOVE FAN/MANIFOLD ASSEMBLY
REMOVE THE BURNER/BAFFLES ASSEMBLY

Next: !p3012, !f3013

COMBUSTION ANALYSIS MAX AND MIN

Next: p3016, ?3018, ?3020

SPARKING PRESENT TEST

REMOVE SPARK LEADS F

Next: p3026, !f3027

INSPECTION GAS SUPPLY TUBE

Next: !p3024, !f3025

INSPECTION GAS SUPPLY TUBE

Next: !p3022, !f3023

CONDENSATE PIPE

Next: p3028, !f3029

INSPECTION FLUE OH STAT

Next: p3030, !f3031

INSPECTION GAS SUPPLY TUBE

Next: p3032, !f3033

ELECTRODE SENSE HARNESS

DISCONNECT FLAME SEN

Next: p3034, !f3035

ELECTRODE SPARK HARNESS

REMOVE THE IGNITION HARNESS CONNECTION FROM THE
ELECTRODES TOP OF THE BURNER AND FROM THE PCB

Next: p3036, !f3037

INSPECTION ELECTRODES

REMOVE THE ELECTRODE ASSEMBLY

Next: p3038, !f3039

INSPECTION FAN MEMBRANE

REMOVE FAN ASSEMBLY FROM APPLIANCE

Next: !p3040, ?3042, ?3044

OBSERVATION FAN TYPE

Next: p3047, f3048

VOLTAGE FAN (AT PCB)

MOVE CONNECTOR ST5 U

Next: p3060, ?3062, ?3064

VOLTAGE FAN (PCB DEMAND)

DISCONNECT ELECTRICA

Next: p3056, !f3057

RESISTANCE FAN HARNESS

DISCONNECT CONNECTOR ST5 FROM THE PCB
DISCONNECT CONNECTOR FROM THE FAN ASSEMBLY

Next: !p3054, !f3055

RESISTANCE FAN HARNESS

DISCONNECT CONNECTOR ST5 FROM THE PCB
DISCONNECT CONNECTOR FROM THE FAN ASSEMBLY

Next: !p3058, !f3059

VOLTAGE FAN (PCB DEMAND)

DISCONNECT ELECTRICA

Next: p3070, !f3071

RESISTANCE FAN HARNESS

DISCONNECT CONNECTOR ST5 FROM THE PCB
DISCONNECT CONNECTOR FROM THE FAN ASSEMBLY

Next: p3066, !f3067

INSPECTION FAN

REMOVE PCB FROM FAN ASSEMBLY (FOR INSTRUCTIONS CLICK HERE)

Next: !p3068, !f3069

RESISTANCE FAN HARNESS

DISCONNECT CONNECTOR ST5 FROM THE PCB
DISCONNECT CONNECTOR FROM THE FAN ASSEMBLY

Next: p3072, !f3073

INSPECTION FAN

REMOVE PCB FROM FAN ASSEMBLY (FOR INSTRUCTIONS CLICK HERE)

Next: !p3074, !f3075

OBSERVATION FAN TYPE

Next: p3078, f3079

FAN VOLTAGE CONTROL (PCB)

{GAINPCBACS}
MOVE CONNECTOR ST5 TO EXPOSE TERMINALS ON PCB

Next: p3091, ?3093, ?3095

RESISTANCE FAN HARNESS

DISCONNECT CONNECTOR ST5 FROM THE PCB
DISCONNECT CONNECTOR FROM THE FAN ASSEMBLY

Next: !p3089, !f3090

RESISTANCE FAN HARNESS

DISCONNECT CONNECTOR ST5 FROM THE PCB
DISCONNECT CONNECTOR FROM THE FAN ASSEMBLY

Next: !p3087, !f3088

RESISTANCE FAN HARNESS

DISCONNECT CONNECTOR ST5 FROM THE PCB
DISCONNECT CONNECTOR FROM THE FAN ASSEMBLY

Next: !p3085, !f3086

RESISTANCE FAN HARNESS

DISCONNECT CONNECTOR ST5 FROM THE PCB
DISCONNECT CONNECTOR FROM THE FAN ASSEMBLY

Next: p3103, !f3104

RESISTANCE FAN HARNESS

DISCONNECT CONNECTOR ST5 FROM THE PCB
DISCONNECT CONNECTOR FROM THE FAN ASSEMBLY

Next: p3099, !f3100

RESISTANCE FAN HARNESS

DISCONNECT CONNECTOR ST5 FROM THE PCB
DISCONNECT CONNECTOR FROM THE FAN ASSEMBLY

Next: !p3097, !f3098

INSPECTION FAN

REMOVE PCB FROM FAN ASSEMBLY (FOR INSTRUCTIONS CLICK HERE)

Next: !p3101, !f3102

INSPECTION FAN

REMOVE PCB FROM FAN ASSEMBLY (FOR INSTRUCTIONS CLICK HERE)

Next: !p3105, !f3106

INSPECTION FAN

REMOVE PCB FROM FAN ASSEMBLY (FOR INSTRUCTIONS CLICK HERE)

Next: !p3112, !f3113

OBSERVATION FAN TYPE

Next: p3116, f3117

FAN VOLTAGE CONTROL (PCB)

{GAINPCBACS}
MOVE CONNECTOR ST5 TO EXPOSE TERMINALS ON PCB

Next: p3129, ?3131, ?3133

RESISTANCE FAN HARNESS

DISCONNECT CONNECTOR ST5 FROM THE PCB
DISCONNECT CONNECTOR FROM THE FAN ASSEMBLY

Next: !p3127, !f3128

RESISTANCE FAN HARNESS

DISCONNECT CONNECTOR ST5 FROM THE PCB
DISCONNECT CONNECTOR FROM THE FAN ASSEMBLY

Next: !p3125, !f3126

RESISTANCE FAN HARNESS

DISCONNECT CONNECTOR ST5 FROM THE PCB
DISCONNECT CONNECTOR FROM THE FAN ASSEMBLY

Next: !p3123, !f3124

RESISTANCE FAN HARNESS

DISCONNECT CONNECTOR ST5 FROM THE PCB
DISCONNECT CONNECTOR FROM THE FAN ASSEMBLY

Next: p3141, !f3142

RESISTANCE FAN HARNESS

DISCONNECT CONNECTOR ST5 FROM THE PCB
DISCONNECT CONNECTOR FROM THE FAN ASSEMBLY

Next: p3137, !f3138

RESISTANCE FAN HARNESS

DISCONNECT CONNECTOR ST5 FROM THE PCB
DISCONNECT CONNECTOR FROM THE FAN ASSEMBLY

Next: !p3135, !f3136

INSPECTION FAN

REMOVE PCB FROM FAN ASSEMBLY (FOR INSTRUCTIONS CLICK HERE)

Next: !p3139, !f3140

INSPECTION FAN

REMOVE PCB FROM FAN ASSEMBLY (FOR INSTRUCTIONS CLICK HERE)

Next: !p3143, !f3144

OBSERVATION FAN TYPE

Next: p3146, f3147

VOLTAGE FAN (AT PCB)

MOVE CONNECTOR ST5 U

Next: p3159, ?3161, ?3163

VOLTAGE FAN (PCB DEMAND)

DISCONNECT ELECTRICA

Next: p3155, !f3156

RESISTANCE FAN HARNESS

DISCONNECT CONNECTOR ST5 FROM THE PCB
DISCONNECT CONNECTOR FROM THE FAN ASSEMBLY

Next: !p3153, !f3154

RESISTANCE FAN HARNESS

DISCONNECT CONNECTOR ST5 FROM THE PCB
DISCONNECT CONNECTOR FROM THE FAN ASSEMBLY

Next: !p3157, !f3158

VOLTAGE FAN (PCB DEMAND)

DISCONNECT ELECTRICA

Next: p3171, !f3172

RESISTANCE FAN HARNESS

DISCONNECT CONNECTOR ST5 FROM THE PCB
DISCONNECT CONNECTOR FROM THE FAN ASSEMBLY

Next: p3177, !f3166

RESISTANCE FAN HARNESS

DISCONNECT CONNECTOR ST5 FROM THE PCB
DISCONNECT CONNECTOR FROM THE FAN ASSEMBLY

Next: p3173, !f3174

INSPECTION FAN

REMOVE PCB FROM FAN ASSEMBLY (FOR INSTRUCTIONS CLICK HERE)

Next: !p3175, !f3176

INSPECTION FAN

REMOVE PCB FROM FAN ASSEMBLY (FOR INSTRUCTIONS CLICK HERE)

Next: !p3178, !f3179

VOLTAGE MAINS GND PWM AND HALL

REMOVE THE CONNECTOR FROM THE FAN AND MAKE SAFE
ENSURE NO DEMANDS

Next: p3053, !f3191

VOLTAGE MAINS GND PWM AND HALL

REMOVE THE CONNECTOR FROM THE FAN AND MAKE SAFE
ENSURE NO DEMANDS

Next: p3065, !f3190

INLET PRESSURE

ATTACH PRESSURE GAUGE TO INLET PRESSURE TEST POINT ON GAS VALVE

Next: p2558, !f393

VOLTAGE MAINS GND PWM AND HALL

REMOVE THE CONNECTOR FROM THE FAN AND MAKE SAFE
ENSURE NO DEMANDS

Next: p3164, !f3202

VOLTAGE MAINS GND PWM AND HALL

REMOVE THE CONNECTOR FROM THE FAN AND MAKE SAFE
ENSURE NO DEMANDS

Next: p3152, !f3203

PUMP LIMPET TEST

Next: p2205, !f926

CONDENSATE PIPE

Next: p989, !f988

INLET PRESSURE

ATTACH PRESSURE GAUGE TO INLET PRESSURE TEST POINT ON GAS VALVE

Next: p990, !f991

FAN PRESSURE TEST (IGNITION)

ATTACH PRESSURE GAUGE TO FAN PRESSURE TEST POINT

Next: p2130, f2873

INSPECTION FLUE

Next: !p1020, !f1011

System Information

  • Total Tests: 507
  • Sequence Logic: Decoded from encrypted .seq file
  • Navigation: Dynamic based on pass/fail results
  • Source: 4731307 GW SWIFTFLOW 100 SIT Control