Set Appliance State:
Mains Power Off
Isolate Mains Power to appliance as per TOPs P4
Observation:
Remove the Spark Electrode and visually check it for signs of damage.
Check the Spark Electrode alignment and gap.
Spark Electrode should be positioned 70mm +/- 3mm from Front of Burner.
Spark Gap from Burner Face should be 16mm +/- 1mm.
Gap between Poles should be 3mm+/- 1mm.
Check the Spark Electrode alignment and gap.
Spark Electrode should be positioned 70mm +/- 3mm from Front of Burner.
Spark Gap from Burner Face should be 16mm +/- 1mm.
Gap between Poles should be 3mm+/- 1mm.
Isolate as per TOPs P4
and refit as necessary