Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Gain access to PCB (use Insulation Mat as required)
Remove the ionisation lead from connector CN04 and make safe
Ensure NO demand
Ensure NO demand
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure for AC voltage between connector CN04
on the main PCB to a suitable earth point.
Expect approximately 85 VAC.
on the main PCB to a suitable earth point.
Expect approximately 85 VAC.

Isolate as per TOPs P4
and refit as necessary