Set Appliance State:

WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Observation:

Test Function activation.
1. Press the Reset button for 5 seconds until the yellow LED flashes, the 60°C LED will also illuminate to indicate the appliance is at MAX CH absolute.
2. Rotate the CH control knob fully clockwise until the 80°C LED illuminates signify that the appliance is operating at MAX heating power (if the CH control is already fully clockwise, then rotate anti-clockwise slightly before rotating back to fully clockwise)
3. The function is automatically deactivated after 10 minutes or by pressing the Reset button.