Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove connector CN09 from the PCB
Disconnect the electrical connection from the pump assembly
Disconnect the electrical connection from the pump assembly
Measurement:
Test 1.
Measure the resistance between pin 2 on the
pump connector and pin 3 on connector CN09.
Test 2.
Measure the resistance between pin 3 on the
pump connector and pin 4 on connector CN09.
Test 3.
Measure the resistance between pin 4 on the
pump connector and pin 1 on connector CN09.
Test 4.
Measure the resistance between pin 1 on the
pump connector and pin 2 on connector CN09.
Expect continuity / zero resistance on each test.
Also visually inspect the condition of the harness.
Measure the resistance between pin 2 on the
pump connector and pin 3 on connector CN09.
Test 2.
Measure the resistance between pin 3 on the
pump connector and pin 4 on connector CN09.
Test 3.
Measure the resistance between pin 4 on the
pump connector and pin 1 on connector CN09.
Test 4.
Measure the resistance between pin 1 on the
pump connector and pin 2 on connector CN09.
Expect continuity / zero resistance on each test.
Also visually inspect the condition of the harness.

Isolate as per TOPs P4
and refit as necessary