Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to AC Volts Set meter to measure AC Volts
CH Demand
Gain access to PCB (use Insulation Mat as required)
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Reset the appliance if required.
(Press reset button once then release)
Allow the fan to run and the ignition sequence to commence.
Measure for mains voltage between pin 3 (brown) and
pin 4 (blue) on connector CN22 at the main PCB.
Mains voltage should be present for 5 seconds, this will then be present again after approximately 7 seconds. This will be repeated 3 times before lockout occurs, reset as required until test is complete.