Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
CH Demand
Gain access to PCB (use Insulation Mat as required)
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Observation:

Reset the appliance if required.
(Press reset button once then release)
Allow the fan to run and the ignition sequence to commence.
Measure for mains voltage between pin 3 (brown) and
pin 4 (blue) on connector CN22 at the main PCB.
Mains voltage should be present for 5 seconds, this will then be present again after approximately 7 seconds. This will be repeated 3 times before lockout occurs, reset as required until test is complete.