Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect CN102 from the control PCB
Measurement:
Test 1:
Measure the resistance between pins 5 and 6 at the disconnected plug.
Resistance should be approximately 19kΩ.
Test 2:
Measure the resistance between pin 8 at the disconnected plug to a suitable earth point.
Resistance should be greater than 1MΩ (or O.L).
Note:
Colour of wires may change but test points remain the same.
Measure the resistance between pins 5 and 6 at the disconnected plug.
Resistance should be approximately 19kΩ.
Test 2:
Measure the resistance between pin 8 at the disconnected plug to a suitable earth point.
Resistance should be greater than 1MΩ (or O.L).
Note:
Colour of wires may change but test points remain the same.

Isolate as per TOPs P4
and refit as necessary