Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to Resistance Set meter to measure resistance
Disconnect leads at the common (C) and normally closed (N/C) terminals on the air pressure switch

Measurement:

Measure the resistance between the common and
normally closed terminals on the air pressure switch.
Expected resistance short circuit (zero resistance).
Note:
Design of APS may differ, refer to information on APS
to ensure you are testing across correct terminals.